Temporal bone: Comparison of isotropic helical CT and conventional direct axial and coronal CT

被引:26
作者
Caldemeyer, KS
Sandrasegaran, K
Shinaver, CN
Mathews, VP
Smith, RR
Kopecky, KK
机构
[1] Indiana Univ Hosp, Dept Radiol, Div Neuroradiol, Indianapolis, IN 46202 USA
[2] Indiana Univ, Sch Med, Dept Radiol, Div Abdominal Imaging, Indianapolis, IN 46202 USA
关键词
D O I
10.2214/ajr.172.6.10350314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of the study was to compare helical CT (with reformation of coronal images from the axial data set) with conventional direct axial and coronal CT of the temporal bones. SUBJECTS AND METHODS. Nineteen patients underwent both conventional 1-mm direct axial and coronal CT and helical 0.5-mm axial CT. The helical data set was reconstructed at 0.2-mm increments, and axial and coronal images were reconstructed in a plane similar to that of the conventional study, with a slice width of 0.5 mm and 0.5-mm increments. Forty small structures were evaluated independently by three observers, who were unaware of the method of imaging. Observers graded the 40 structures using a modified Likert scale. The graded differences between the two techniques were evaluated using a paired t test. Correlation between observers' gradings was evaluated using analysis of variance. RESULTS. The helical CT technique scored significantly higher than the conventional technique for many individual structures and groups of structures (scutum [p = .041], stapes footplate [p = .006], stapes crura [p = .004], oval window [p = .026], crista falciformis [p = .006], whole temporal bone [p =.012], middle ear [p = .033], inner ear [p = .021], ossicles [p.044], and stapes [p =.010]). The correlation coefficient among observers was .91 for the whole temporal bone. CONCLUSION. Helical CT using 0.5-mm technique and reconstruction produces diagnostic images comparable with or superior to conventional I-mm technique because helical CT can obtain thinner slices.
引用
收藏
页码:1675 / 1682
页数:8
相关论文
共 9 条
[1]  
CHAKERES DW, 1996, HEAD NECK IMAGING, P1319
[2]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[3]  
HERMANS R, 1995, NEURORADIOLOGY, V37, P150
[4]   Effect of helical CT on the frequency of sedation in pediatric patients [J].
Kaste, SC ;
Young, CW ;
Holmes, TP ;
Baker, DK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) :1001-1003
[5]  
LEE BCP, 1989, AM J NEURORADIOL, V10, P431
[6]  
Lemmerling MM, 1997, AM J NEURORADIOL, V18, P471
[7]  
LUKER GD, 1993, AM J NEURORADIOL, V14, P1145
[8]   DIRECT SAGITTAL CT IN THE EVALUATION OF TEMPORAL BONE-DISEASE [J].
MAFEE, MF ;
KUMAR, A ;
TAHMORESSI, CN ;
LEVIN, BC ;
JAMES, CF ;
KRIZ, R ;
CAPEK, V .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) :1403-1410
[9]   CURRENT IMAGING APPROACH TO THE TEMPORAL BONE [J].
SWARTZ, JD .
RADIOLOGY, 1989, 171 (02) :309-317