Monitoring method of rice seeds mass in vibrating tray for vacuum-panel precision seeder

被引:67
作者
Zhao Zhan [1 ]
Wu Yafang [1 ]
Yin Jianjun [1 ]
Tang Zhong [1 ]
机构
[1] Jiangsu Univ, Minist Educ & Jiangsu Prov, Key Lab Modern Agr Equipment & Technol, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Seeds mass; Monitoring method; Vibrating tray; Impact force; Discrete element method; DISCRETE ELEMENT METHOD; SPACING UNIFORMITY PERFORMANCE; SIMULATION; OPTIMIZATION; SEPARATION; PARTICLES; DESIGN;
D O I
10.1016/j.compag.2015.03.007
中图分类号
S [农业科学];
学科分类号
082806 [农业信息与电气工程];
摘要
According to the physical properties of rice seeds, triaxial ellipsoidal particle models were established based on the multi-sphere approach, and simulations of seeds motion in a vibrating tray were performed using the discrete element method (DEM). It was shown that the normal impact force F-n of seeds action on the tray was mainly composed of transient impact and accumulation force sections. The value of transient impact force was not stable because it was influenced comprehensively by shape of seed, vibration parameter and seeds-mass-per-unit-area (SMA). The variation of accumulation force determined by impulse change of seeds was relatively stable. Simulation results indicated that its value was almost linearly varied with SMA under a certain vibration parameter, and a real-time monitoring method of seeds mass in a vibrating tray is presented in this paper. Two cantilever force sensors were back-to-back fixed at the bottom of seed tray. Due to a phasic difference psi existed between the vibration inertia force and the seeds normal impact force F-n, a differential operation was performed between the output signals of two sensors to eliminate the influence of inertia force and extract F-n, effectively. Then, a signal processing circuit mainly composed of differential amplifier, active low-pass filter, bias voltage circuit, envelope detector, and passive low-pass filter in series was designed to detect seeds mass. Calibration tests were carried out in laboratory with vibration frequency f and amplitude A of tray in the ranges of 9-13 Hz and 3-5 mm, the results showed that the comprehensive measurement errors were <3.5% with SMA kappa in the range of 0.2-1.8 g/cm(2). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 25 条
[1]
Barut Zeliha Bereket, 2004, Turkish Journal of Agriculture and Forestry, V28, P435
[2]
A new algorithm for contact detection between convex polygonal and polyhedral particles in the discrete element method [J].
Boon, C. W. ;
Houlsby, G. T. ;
Utili, S. .
COMPUTERS AND GEOTECHNICS, 2012, 44 :73-82
[3]
Chen Jin Chen Jin, 2011, Nongye Jixie Xuebao = Transactions of the Chinese Society for Agricultural Machinery, V42, P79
[4]
Design of a low-cost pneumatic seeder for nursery plug trays [J].
Gaikwad, B. B. ;
Sirohi, N. P. S. .
BIOSYSTEMS ENGINEERING, 2008, 99 (03) :322-329
[5]
[龚智强 Gong Zhiqiang], 2012, [机械设计与研究, Machine Design and Research], V28, P15
[6]
Experimental and theoretical performance of a vacuum seeder nozzle for vegetable seeds [J].
Guarella, P ;
Pellerano, A ;
Pascuzzi, S .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1996, 64 (01) :29-36
[7]
He RuiYin He RuiYin, 2008, Transactions of the Chinese Society of Agricultural Engineering, V24, P167
[8]
Mathematical modelling of vacuum pressure on a precision seeder [J].
Karayel, D ;
Barut, ZB ;
Özmerzi, A .
BIOSYSTEMS ENGINEERING, 2004, 87 (04) :437-444
[10]
Grain velocity distribution in a mixed flow dryer [J].
Keppler, Istvan ;
Kocsis, Laszlo ;
Oldal, Istvan ;
Farkas, Istvan ;
Csatar, Attila .