A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement

被引:135
作者
Ursino, M [1 ]
Cristalli, C [1 ]
机构
[1] CASE WESTERN RESERVE UNIV, CTR ELECTR DESIGN, CLEVELAND, OH 44106 USA
关键词
D O I
10.1109/10.508540
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A mathematical lumped parameter model of the oscillometric technique for indirect blood pressure measurement is presented, The model includes cuff compliance, pressure transmission from the cuff to the brachial artery through the soft tissue of the arm, and the biomechanics of the brachial artery both at positive and negative transmural pressure values. The main aspects of oscillometry are simulated i.e., the increase in cuff pressure pulsatility during cuff deflation maneuvers, the existence of a point of maximum pulsations (about 1.5 mmHg) at a cuff pressure close to mean arterial pressure, and the characteristic ratios for cuff pressure pulsatility at systole and diastole (0.52 and 0.70, respectively, with this model, using basal parameters and an individual set of data for the arterial pressure waveform), Subsequently, the model is used to examine how alterations in some biomechanical factors may prejudice the accuracy of pressure measurement, Numerical simulations indicate that alterations in wall viscoelastic properties and in arterial pressure pulse amplitude may significantly affect the accuracy of pressure estimates, leading to errors as great as 15-20% in the computation of diastolic and systolic arterial pressure. By contrast, changes in arterial pressure mean value and cuff compliance do not seem to have significant influence on the measurement, Evaluation of mean arterial pressure through a characteristic ratio is not robust and may lead to misleading results, Mean arterial pressure may be better evaluated as the lowest pressure at which cuff pulse amplitude reaches a plateau, The obtained results may help to explain the nature of errors which usually limit the reliability of arterial pressure measurement (for instance in the elderly).
引用
收藏
页码:761 / 778
页数:18
相关论文
共 35 条
[1]   CRITERIA IN CHOICE OF AN OCCLUDING CUFF FOR INDIRECT MEASUREMENT OF BLOOD-PRESSURE [J].
ALEXANDER, H ;
COHEN, ML ;
STEINFELD, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (01) :2-10
[2]   MULTI-BRANCHED MODEL OF THE HUMAN ARTERIAL SYSTEM [J].
AVOLIO, AP .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (06) :709-718
[3]   DYNAMIC ELASTIC PROPERTIES OF ARTERIAL WALL [J].
BERGEL, DH .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03) :458-&
[4]  
BRACE RA, 1977, P SOC EXP BIOL MED, V154, P164
[5]  
CAWS Peter., 1988, STRUCTURALISM ART IN
[6]  
Cristalli C., 1995, Measurement, V14, P229, DOI 10.1016/0263-2241(94)00029-7
[7]   MECHANICS OF THE OCCLUSIVE ARM CUFF AND ITS APPLICATION AS A VOLUME SENSOR [J].
DRZEWIECKI, G ;
BANSAL, V ;
KARAM, E ;
HOOD, R ;
APPLE, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (07) :704-708
[8]   THEORY OF THE OSCILLOMETRIC MAXIMUM AND THE SYSTOLIC AND DIASTOLIC DETECTION RATIOS [J].
DRZEWIECKI, G ;
HOOD, R ;
APPLE, H .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (01) :88-96
[9]   THE KOROTKOFF SOUND [J].
DRZEWIECKI, GM ;
MELBIN, J ;
NOORDERGRAAF, A .
ANNALS OF BIOMEDICAL ENGINEERING, 1989, 17 (04) :325-359
[10]   BLOOD-PRESSURE MEASUREMENT IN THE ELDERLY - CORRELATION OF ARTERIAL STIFFNESS WITH DIFFERENCE BETWEEN INTRA-ARTERIAL AND CUFF PRESSURES [J].
FINNEGAN, TP ;
SPENCE, JD ;
WONG, DG ;
WELLS, GA .
JOURNAL OF HYPERTENSION, 1985, 3 (03) :231-235