Model-Based Tomographic Reconstruction of Objects Containing Known Components

被引:66
作者
Stayman, J. Webster [1 ]
Otake, Yoshito [2 ]
Prince, Jerry L. [3 ]
Khanna, A. Jay [4 ]
Siewerdsen, Jeffrey H. [2 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Biomed Engn & Comp Sci, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[4] Johns Hopkins Univ, Dept Orthopaed Surg, Baltimore, MD 21205 USA
关键词
CT reconstruction; implant imaging; metal artifact reduction; penalized-likelihood estimation; STATISTICAL IMAGE-RECONSTRUCTION; RAY COMPUTED-TOMOGRAPHY; METAL-ARTIFACT SUPPRESSION; 3-DIMENSIONAL FLUOROSCOPY; STREAK ARTIFACTS; EM ALGORITHM; C-ARM; REDUCTION; PROJECTION; GUIDANCE;
D O I
10.1109/TMI.2012.2199763
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The likelihood of finding manufactured components (surgical tools, implants, etc.) within a tomographic field-of-view has been steadily increasing. One reason is the aging population and proliferation of prosthetic devices, such that more people undergoing diagnostic imaging have existing implants, particularly hip and knee implants. Another reason is that use of intraoperative imaging (e. g., cone-beam CT) for surgical guidance is increasing, wherein surgical tools and devices such as screws and plates are placed within or near to the target anatomy. When these components contain metal, the reconstructed volumes are likely to contain severe artifacts that adversely affect the image quality in tissues both near and far from the component. Because physical models of such components exist, there is a unique opportunity to integrate this knowledge into the reconstruction algorithm to reduce these artifacts. We present a model-based penalized-likelihood estimation approach that explicitly incorporates known information about component geometry and composition. The approach uses an alternating maximization method that jointly estimates the anatomy and the position and pose of each of the known components. We demonstrate that the proposed method can produce nearly artifact-free images even near the boundary of a metal implant in simulated vertebral pedicle screw reconstructions and even under conditions of substantial photon starvation. The simultaneous estimation of device pose also provides quantitative information on device placement that could be valuable to quality assurance and verification of treatment delivery.
引用
收藏
页码:1837 / 1848
页数:12
相关论文
共 47 条
[1]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[2]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[3]  
Chun SY, 2009, PHYS MED IM
[4]   Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance [J].
Daly, B ;
Krebs, TL ;
Wong-You-Cheong, JJ ;
Wang, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) :637-644
[5]   An iterative maximum-likelihood polychromatic algorithm for CT [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (10) :999-1008
[6]  
De Man B, 1999, IEEE T NUCL SCI, V46, P691, DOI 10.1109/23.775600
[7]   Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :977-981
[8]   ON THE RELATION BETWEEN THE ISRA AND THE EM ALGORITHM FOR POSITRON EMISSION TOMOGRAPHY [J].
DEPIERRO, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :328-333
[9]   Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation [J].
Elbakri, IA ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15) :2453-2477
[10]   Statistical image reconstruction for polyenergetic X-ray computed tomography [J].
Elbakri, IA ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :89-99