High-resolution maps of regional ventilation utilizing inhaled fluorescent microspheres

被引:79
作者
Robertson, HT
Glenny, RW
Stanford, D
McInnes, LM
Luchtel, DL
Covert, D
机构
[1] UNIV WASHINGTON, DEPT ATMOSPHER SCI, SEATTLE, WA 98195 USA
[2] UNIV WASHINGTON, DEPT ENVIRONM HLTH & STAT, SEATTLE, WA 98195 USA
关键词
pulmonary aerosol deposition; ventilation heterogeneity; ventilation-perfusion heterogeneity; gravitational gradient; radial gradient; pigs;
D O I
10.1152/jappl.1997.82.3.943
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The regional deposition of an inhaled aerosol of 1.0-mu m diameter fluorescent microspheres (FMS) was used to produce high-resolution maps of regional ventilation. Five anesthetized, prone, mechanically ventilated pigs received two 10-min inhalations of pairs of different FMS labels, accompanied by intravenous injection of 15.0-mu m radioactive microspheres. The lungs were air dried and cut into 1.9-cm(3) pieces, with notation of the spatial coordinates for each piece. After measurement of radioactive energy peaks, the tissue samples were soaked in 2-ethoxyethyl acetate, and fluorescent emission peaks were recorded for the wavelengths specific to each fluorescence label. The correlation of fluorescence activity between simultaneously administered inhaled FMS ranged from 0.98 to 0.99. The mean coefficient of variation for ventilation for all 10 trials (47.9 +/- 8.1%) was similar to that for perfusion (46.2 +/- 6.3%). No physiologically significant gravitational gradient of ventilation or perfusion was present in the prone animals. The strongest predictor of the magnitude of regional ventilation among all animals was regional perfusion (r = 0.77 +/- 0.13).
引用
收藏
页码:943 / 953
页数:11
相关论文
共 26 条
[1]  
AMIS TC, 1990, EUR RESPIR J, V3, P679
[2]   DIFFERENCES IN REGIONAL VASCULAR CONDUCTANCES IN ISOLATED DOG LUNGS [J].
BECK, KC ;
REHDER, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) :530-538
[3]  
BRAIN JD, 1979, AM REV RESPIR DIS, V120, P1325
[4]   EFFECTS OF PULMONARY BLOOD-FLOW ON THE FRACTAL NATURE OF FLOW HETEROGENEITY IN SHEEP LUNGS [J].
CARUTHERS, SD ;
HARRIS, TR .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (03) :1474-1479
[5]   Two- and three-dimensional simulations of aerosol transport and deposition in alveolar zone of human lung [J].
Darquenne, C ;
Paiva, N .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (04) :1401-1414
[6]   ONE-DIMENSIONAL SIMULATION OF AEROSOL TRANSPORT AND DEPOSITION IN THE HUMAN LUNG [J].
DARQUENNE, C ;
PAIVA, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (06) :2889-2898
[7]  
Draper N., 1981, APPL REGRESSION ANAL
[8]  
*FMRC, 1996, FMS MAN US FLUOR MIC
[9]   TEMPORAL HETEROGENEITY OF REGIONAL PULMONARY PERFUSION IS SPATIALLY CLUSTERED [J].
GLENNY, RW ;
POLISSAR, NL ;
MCKINNEY, S ;
ROBERTSON, HT .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (03) :986-1001
[10]   FRACTAL PROPERTIES OF PULMONARY BLOOD-FLOW - CHARACTERIZATION OF SPATIAL HETEROGENEITY [J].
GLENNY, RW ;
ROBERTSON, HT .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (02) :532-545