Hepatic sonography: Comparison of tissue harmonic and standard sonography techniques

被引:80
作者
Hann, LE
Bach, AM
Cramer, LD
Siegel, D
Yoo, HH
Garcia, R
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, New York, NY 10021 USA
关键词
D O I
10.2214/ajr.173.1.10397127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, This study was performed to compare tissue harmonic sonography of the liver with conventional sonography of the liver, SUBJECTS AND METHODS. Forty-eight patients underwent tissue harmonic and conventional sonography of the liver using a randomized imaging sequence. Imaging parameters were standardized, but gain varied. Techniques were compared using predetermined impact analysis categories. If a finding was revealed by only one sonographic technique, additional confirmation was obtained by another imaging technique or by surgery. In a separate image quality analysis, masked images were reviewed by two experienced radiologists to evaluate fluid-solid differentiation, near-field, far-field, and overall image quality. Rankings were correlated with field of view of images and body habitus of patients as determined by body mass index. RESULTS. Tissue harmonic sonography provided the same information as conventional sonography in 34 patients (71%) and added information in 14 patients (29%). The findings from tissue harmonic sonography resulted in altered treatment in five patients (10%), Eight patients (17%) had lesions revealed by tissue harmonic sonography only. Four patients (8%) had inadequate far-field visualization by both techniques. Both observers ranked tissue harmonic sonography the same as or better than standard sonography in 46 patients (96%) for fluid-solid differentiation, in 46 patients (96%) for near-field image quality, and in 45 patients (94%) for overall image quality. For far-field image quality, one observer ranked tissue harmonic sonography the same as or better than conventional sonography in 40 patients (83%), and the second observer, in 41 patients (85%). Image quality ratings showed no correlation with body habitus of the patients or field of view of images. CONCLUSION. Tissue harmonic sonography of the liver provides more information and better image quality than does conventional sonography of the liver.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 10 条
[1]   Finite amplitude distortion and its relationship to linear derating formulae for diagnostic ultrasound systems [J].
Christopher, T ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :1103-1116
[2]   Real-time assessment of the parameter of nonlinearity in tissue using ''nonlinear shadowing'' [J].
Fatemi, M ;
Greenleaf, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) :1215-1228
[3]   Harmonic amplitude distribution in a wideband ultrasonic wavefront after propagation through human abdominal wall and breast specimens [J].
Liu, DL ;
Waag, RC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) :1172-1183
[4]   PREDICTION OF NON-LINEAR ACOUSTIC EFFECTS AT BIOMEDICAL FREQUENCIES AND INTENSITIES [J].
MUIR, TG ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (04) :345-357
[5]  
OLEFSKY JM, 1994, HARRISONS PRINCIPLES, P446
[6]  
PELLERITO JS, 1998, AJR, V170, P31
[7]   Tissue harmonic imaging sonography: Evaluation of image quality compared with conventional sonography [J].
Shapiro, RS ;
Wagreich, J ;
Parsons, RB ;
Stancato-Pasik, A ;
Yeh, HC ;
Lao, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1203-1206
[8]   THE DEVELOPMENT OF HARMONIC DISTORTION IN PULSED FINITE-AMPLITUDE ULTRASOUND PASSING THROUGH LIVER [J].
STARRITT, HC ;
DUCK, FA ;
HAWKINS, AJ ;
HUMPHREY, VF .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (12) :1401-1409
[9]   EVIDENCE FOR ULTRASONIC FINITE-AMPLITUDE DISTORTION IN MUSCLE USING MEDICAL EQUIPMENT [J].
STARRITT, HC ;
PERKINS, MA ;
DUCK, FA ;
HUMPHREY, VF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (01) :302-306
[10]   Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound [J].
Ward, B ;
Baker, AC ;
Humphrey, VF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01) :143-154