A nested case-control study of residential and personal magnetic field measures and miscarriages

被引:85
作者
Lee, GM
Neutra, RR
Hristova, L
Yost, M
Hiatt, RA
机构
[1] Calif Dept Hlth Serv, Environm Hlth Invest Branch, Oakland, CA 94612 USA
[2] Univ Washington, Dept Environm Hlth, Seattle, WA 98195 USA
[3] NCI, Div Canc Control & Populat Sci, Bethesda, MD 20892 USA
关键词
miscarriage; spontaneous abortion; magnetic fields; electromagnetic fields; maternal exposure; wire codes;
D O I
10.1097/00001648-200201000-00005
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
We conducted a nested case-control study (177 cases, 550 controls) to assess the relation between retrospective magnetic field measures and clinical miscarriage among members of the northern California Kaiser Permanente medical care system. We also conducted a prospective substudy of 219 participants of the same parent cohort to determine whether 12-week and 30-week exposure assessments were similar. We evaluated wire codes, area measures, and three personal meter metrics: (1) the average difference between consecutive levels (a rate,of-change metric), (2) the maximum level, and (3) the time-weighted average. For wire codes and area measures we found little association. For the personal metrics (30 weeks after last menstrual period), we found positive associations. Each exposure was divided into quartiles, with the lowest quartile as referent. Starting with the highest quartile, adjusted odds ratios and 95% confidence intervals were 3.1 (95% CI = 1.6-6.0), 2.3 (95% CI = 1.2-4.4), and 1.5 (95% CI = 0.8-3.1) for the rate-ofchange metric; 2.3 (95% CI = 1.24-4), 1.9 (95% CI = 1.0-3.5), and 1.4 (95% CI = 0.7-2.8) for the maximum value; and 1.7 (95% CI = 0.9-3.3), 1.7 (95% CI = 0.9-3.3), and 1.7 (95% CI = 0.9-3.3) for the time-weighted average. The odds ratio conveyed by being above a 24-hour time-weighted average of 2 milligauss was 1.0 (95% Cl = 0.5-2.1). Exposure assessment measurements at 12 weeks were poorly correlated with those taken at 30 weeks. Nonetheless, the prospective substudy results regarding miscarriage risk were consistent with the nested study results.
引用
收藏
页码:21 / 31
页数:11
相关论文
共 24 条
[1]  
[Anonymous], IARC SCI PUB
[2]   Spontaneous abortion and exposure to electric blankets and heated water beds [J].
Belanger, K ;
Leaderer, B ;
Hellenbrand, K ;
Holford, TR ;
McSharry, JE ;
Power, ME ;
Bracken, MB .
EPIDEMIOLOGY, 1998, 9 (01) :36-42
[3]  
DELGADO JMR, 1982, J ANAT, V134, P533
[4]   EPIDEMIOLOGIC STUDIES OF WORK WITH VIDEO DISPLAY TERMINALS AND ADVERSE PREGNANCY OUTCOMES (1984-1992) [J].
DELPIZZO, V .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1994, 26 (04) :465-480
[5]   PHYSICAL EXERTION AS A RISK FACTOR FOR SPONTANEOUS-ABORTION [J].
ESKENAZI, B ;
FENSTER, L ;
WIGHT, S ;
ENGLISH, P ;
WINDHAM, GC ;
SWAN, SH .
EPIDEMIOLOGY, 1994, 5 (01) :6-13
[6]  
Farrell JM, 1997, BIOELECTROMAGNETICS, V18, P431, DOI 10.1002/(SICI)1521-186X(1997)18:6<431::AID-BEM5>3.0.CO
[7]  
2-3
[8]   DEVELOPMENT OF CHICK-EMBRYOS IN 1 HZ TO 100 KHZ MAGNETIC-FIELDS [J].
JUUTILAINEN, J ;
SAALI, K .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1986, 25 (02) :135-140
[9]   EARLY-PREGNANCY LOSS AND EXPOSURE TO 50-HZ MAGNETIC-FIELDS [J].
JUUTILAINEN, J ;
MATILAINEN, P ;
SAARIKOSKI, S ;
LAARA, E ;
SUONIO, S .
BIOELECTROMAGNETICS, 1993, 14 (03) :229-236
[10]   The use of electric bed heaters and the risk of clinically recognized spontaneous abortion [J].
Lee, GM ;
Neutra, RR ;
Hristova, L ;
Yost, M ;
Hiatt, RA .
EPIDEMIOLOGY, 2000, 11 (04) :406-415