Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group

被引:43
作者
Fippel, M
Kawrakow, I
Friedrich, K
机构
[1] Clin. of Radiat. Ther. and Oncology, Radiological Centre, University of Leipzig, 04103 Leipzig
关键词
D O I
10.1088/0031-9155/42/3/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The accuracy of the Monte Carlo algorithm for fast electron dose calculation, VMC, is demonstrated by comparing calculations with measurements performed by a working group of the National Cancer Institute (NCI) of the USA. For both energies investigated, 9 and 20 MeV, the measurements in water are taken to determine the energy spectra of the Varian Clinac 1800 accelerator. For the majority of the experiments a good agreement is found between measurements and VMC calculations. However, in some cases deviations have been observed, which could be explained by the incompletely known geometry on the one hand and by inconsistent data on the other hand. As a reference, dose distributions calculated by the MDAH pencil-beam algorithm are also presented. It is shown that, especially near low- or high-density inhomogeneities, large dose overestimations and underestimations are calculated by using a pencil-beam approach, whereas VMC is able to reproduce the correct doses for these cases also.
引用
收藏
页码:501 / 520
页数:20
相关论文
共 25 条
[1]  
BENDL R, 1993, COMPUTER ASSISTED RA, P676
[2]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[3]   ELECTRON-BEAM DOSE PLANNING USING DISCRETE GAUSSIAN BEAMS - MATHEMATICAL BACKGROUND [J].
BRAHME, A ;
LAX, I ;
ANDREO, P .
ACTA RADIOLOGICA ONCOLOGY, 1981, 20 (02) :147-158
[4]   Systematic verification of a three-dimensional electron beam dose calculation algorithm [J].
Cheng, A ;
Harms, WB ;
Gerber, RL ;
Wong, JW ;
Purdy, JA .
MEDICAL PHYSICS, 1996, 23 (05) :685-693
[5]   MULTIPLE SCATTERING WITH ENERGY LOSS [J].
EYGES, L .
PHYSICAL REVIEW, 1948, 74 (10) :1534-1535
[6]  
FRAASS BA, 1996, COMMUNICATION
[7]  
HALBLEIB JA, 1984, SAND840573 SAND NAT
[8]   ELECTRON-BEAM DOSE CALCULATIONS [J].
HOGSTROM, KR ;
MILLS, MD ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :445-459
[9]   DOSIMETRIC EVALUATION OF A PENCIL-BEAM ALGORITHM FOR ELECTRONS EMPLOYING A TWO-DIMENSIONAL HETEROGENEITY CORRECTION [J].
HOGSTROM, KR ;
MILLS, MD ;
MEYER, JA ;
PALTA, JR ;
MELLENBERG, DE ;
MEOZ, RT ;
FIELDS, RS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (04) :561-569
[10]  
Hogstrom KR, 1987, AAPM MONOGRAPH, V15, P532