A multivariate approach to registration of dissimilar tomographic images

被引:12
作者
Andersson, JLR
Thurfjell, L
机构
[1] Inst Neurol, Wellcome Dept Cognit Neurol, London WC1N 3BG, England
[2] Uppsala Univ, PET Ctr, Uppsala, Sweden
[3] Uppsala Univ, Ctr Image Anal, Uppsala, Sweden
基金
英国惠康基金;
关键词
registration; positron emission tomography; multivariate; mutual information;
D O I
10.1007/s002590050443
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We devised a method to allow for retrospective registration of tomographic images with very different information content, the main emphasis being on sets of positron emission tomography images obtained with different tracers. A multivariate cost-function based on information theory was used as an index of "goodness-of-alignment". The cost-function makes no assumptions regarding the form of the relationship between the two image sets, and is hence very general. Image volumes, with known relative spatial orientation, were simulated for tracers with different uptake patterns and the method was validated by assessing its ability to recover these known orientations. The method was able to recover the known transformations with an accuracy of about 1 mm and 1 degrees along and around all axes, even for tracer combinations with radically different uptake patterns and with large initial misalignment. With the suggested method it is feasible to retrospectively align examinations obtained with different tracers and/or modalities.
引用
收藏
页码:718 / 733
页数:16
相关论文
共 46 条
[1]   Registration of dynamic dopamine D-2 receptor images using principal component analysis [J].
Acton, PD ;
Pilowsky, LS ;
Suckling, J ;
Brammer, MJ ;
Ell, PJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (11) :1405-1412
[2]  
ANDERSSON JLR, 1995, J NUCL MED, V36, P1307
[3]  
ANDERSSON JLR, 1995, J NUCL MED, V36, P657
[4]   Implementation and validation of a fully automatic system for intra- and interindividual registration of PET brain scans [J].
Andersson, JLR ;
Thurfjell, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :136-144
[5]   How to obtain high-accuracy image registration: application to movement correction of dynamic positron emission tomography data [J].
Andersson, JLR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (06) :575-586
[6]   Registration of multitracer PET data [J].
Andersson, JLR .
QUANTITATIVE FUNCTIONAL BRAIN IMAGING WITH POSITRON EMISSION TOMOGRAPHY, 1998, :91-97
[7]   A FULLY-AUTOMATIC MULTIMODALITY IMAGE REGISTRATION ALGORITHM [J].
ARDEKANI, BA ;
BRAUN, M ;
HUTTON, BF ;
KANNO, I ;
IIDA, H .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (04) :615-623
[8]   A metric for testing the accuracy of cross-modality image registration: Validation and application [J].
Black, KJ ;
Videen, TO ;
Perlmutter, JS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) :855-861
[9]  
COLLIGNON A, 1995, COMP IMAG VIS, V3, P263
[10]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205