Evaluation of eye irritation potential: Statistical analysis and tier testing strategies

被引:15
作者
deSilva, O
Cottin, M
Dami, N
Roguet, R
Catroux, P
Toufic, A
Sicard, C
Dossou, KG
Gerner, I
Schlede, E
Spielmann, H
Gupta, KC
Hill, RN
机构
[1] BUNDESINST GESUNDHEITLICHEN VERBRAUCHERSCHUTZ & V,ABT CHEMIKALIENBEWERTUNG,D-14195 BERLIN,GERMANY
[2] ZEBET BGVV,D-12277 BERLIN,GERMANY
[3] US CONSUMER PROD SAFETY COMMISS,BETHESDA,MD 20207
[4] US EPA,WASHINGTON,DC 20460
关键词
D O I
10.1016/S0278-6915(96)00105-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Eye irritation testing, specifically the Draize test, has been the centre of controversy for many reasons. Several alternatives, based on the principles of reduction, refinement and replacement, have been proposed and are being used by the industry and government authorities. However, no universally applicable, validated non-animal alternative(s) is currently available. This report presents a statistical analysis and two testing approaches: the partial least squares multivariate statistical analysis of de Silva and colleagues from France, the tier-testing approach for regulatory purposes described by Gerner and colleagues from Germany, and the three-step tier-testing approach of the US Interagency Regulatory Alternatives Group described by Gupta and Hill. These approaches were presented as three separate papers at the November 1993 Interagency Regulatory Alternatives Group (IRAG) Workshop on Eye Irritation Testing; they have been summarized and combined into the following three-part report. The first part (de Silva el al.) presents statistical techniques for establishing test batteries of in vitro alternatives to the eye irritation test. The second (Gerner et nl.) and third (Gupta and Hill) parts are similar in that they stage assessment of information by using a combination of screening information and animal testing to effect reductions in animal use and distress. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 9 条
[1]   TOXICITY DETERMINED INVITRO BY MORPHOLOGICAL ALTERATIONS AND NEUTRAL RED ABSORPTION [J].
BORENFREUND, E ;
PUERNER, JA .
TOXICOLOGY LETTERS, 1985, 24 (2-3) :119-124
[2]  
BULICH AA, 1979, ASTM, V667, P9
[3]   BOVINE CORNEAL OPACITY AND PERMEABILITY TEST - AN INVITRO ASSAY OF OCULAR IRRITANCY [J].
GAUTHERON, P ;
DUKIC, M ;
ALIX, D ;
SINA, JF .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1992, 18 (03) :442-449
[4]  
GORDON VC, 1992, ATLA-ALTERN LAB ANIM, V20, P537
[5]   AGAR DIFFUSION METHOD FOR TOXICITY SCREENING OF PLASTICS ON CULTURED CELL MONOLAYERS [J].
GUESS, WL ;
ROSENBLU.SA ;
SCHMIDT, B ;
AUTIAN, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1965, 54 (10) :1545-&
[6]   PARTIAL LEAST-SQUARES METHOD FOR SPECTROFLUORIMETRIC ANALYSIS OF MIXTURES OF HUMIC-ACID AND LIGNINSULFONATE [J].
LINDBERG, W ;
PERSSON, JA ;
WOLD, S .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :643-648
[7]   HENS EGG CHORIOALLANTOIC MEMBRANE TEST FOR IRRITATION POTENTIAL [J].
LUEPKE, NP .
FOOD AND CHEMICAL TOXICOLOGY, 1985, 23 (02) :287-291
[8]   DETECTION OF CELL-AFFECTING AGENTS WITH A SILICON BIOSENSOR [J].
PARCE, JW ;
OWICKI, JC ;
KERCSO, KM ;
SIGAL, GB ;
WADA, HG ;
MUIR, VC ;
BOUSSE, LJ ;
ROSS, KL ;
SIKIC, BI ;
MCCONNELL, HM .
SCIENCE, 1989, 246 (4927) :243-247
[9]  
Wold S., 1983, P UFOST C FOOD RES D