A technique to visualize corneal incision and lamellar dissection depth during surgery

被引:73
作者
Melles, GRJ [1 ]
Rietveld, FJR [1 ]
Beekhuis, WH [1 ]
Binder, PS [1 ]
机构
[1] Rotterdam Eye Hosp, Cornea Serv, NL-3000 LM Rotterdam, Netherlands
关键词
corneal surgery; air; corneal thickness; incision depth; keratotomy incision; corneal lamellar dissection;
D O I
10.1097/00003226-199901000-00014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose, To describe a surgical technique to visualize the depth of corneal incisions and lamellar stromal dissections during surgery. Methods. In porcine cadaver eyes, the aqueous was exchanged by air. Thus an air-to-endothelium interface (i.e., a useful optical surface) was created at the posterior corneal surface. The air-to-endothelium interface was used as a reference plane to visualize the corneal thickness and the relative depth of corneal incisions and dissections. Freehand peripheral corneal incisions, tangential keratotomy incisions, and lamellar stromal dissections were made at an intended corneal depth of 60, 80, and 99%. Light microscopy was used to measure the relative depth of the incisions and dissections. Results, Achieved depth for peripheral corneal incisions averaged 65.2 +/- 5.3%, 78.8 +/- 5.1%, and 93.4 +/- 6.0%, respectively (p < 0.05); and for tangential keratotomy incisions, 68.2 +/- 7.3%, 83.2 +/- 4.4%, and 95.8 +/- 3.6%, respectively (p < 0.05). Achieved depth for lamellar stromal dissections averaged 58.3 +/- 9.4%, 81.1 +/- 3.4%, and 94.4 +/- 1.5%, respectively (p < 0.05). Microperforations occurred with three incisions made at 99% intended depth. Conclusion, During surgery, the depth of incisions and lamellar dissections relative to the corneal thickness can be visualized by filling the anterior chamber with air (i.e., by creating an optical interface at the posterior corneal surface).
引用
收藏
页码:80 / 86
页数:7
相关论文
共 21 条
  • [1] STRATEGIES FOR THE MANAGEMENT OF MICROBIAL KERATITIS
    ALLAN, BDS
    DART, JKG
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (08) : 777 - 786
  • [2] ARNETSEN JJ, 1987, CORNEAL SURGERY THEO, P416
  • [3] BARRAQUER J, 1984, MICROSURGERY CORNEA, P103
  • [4] BARRAQUER J, 1984, MICROSURGERY CORNEA, P195
  • [5] BINDER PS, 1983, ARCH OPHTHALMOL-CHIC, V101, P1113
  • [6] THE EFFECT OF AIR ON HUMAN CORNEAL ENDOTHELIUM
    EIFERMAN, RA
    WILKINS, EL
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1981, 92 (03) : 328 - 331
  • [7] EISNER G, 1990, EYE SURGERY, P145
  • [8] HTORNTON SP, 1992, REFRACTIVE KERATOTOM, P407
  • [9] KATZ M, 1993, DUANES CLIN OPHTHALM, V1, pCH33
  • [10] Corneal endothelial damage by air bubbles during phacoemulsification
    Kim, EK
    Cristol, SM
    Geroski, DH
    McCarey, BE
    Edelhauser, HF
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (01) : 81 - 88