Fluorescence line-narrowing spectroscopy of analytes deposited on thin-layer chromatography plates

被引:5
作者
Kok, SS [1 ]
Bakker, I [1 ]
Gooijer, C [1 ]
Brinkman, UAT [1 ]
Velthorst, NH [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem, NL-1081 HV Amsterdam, Netherlands
关键词
fluorescence line-narrowing spectroscopy (FLNS); thin-layer chromatography (TLC); analyte;
D O I
10.1016/S0003-2670(99)00155-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity and potential robustness of fluorescence Line-narrowing spectroscopy (FLNS) coupled with column liquid chromatography (LC) in a semi-on-line mode by depositing the analytes on a thin-layer chromatography (TLC) plate was studied with emphasis on analyte identification. Parameters considered were the type of TLC material, the liquid used to ensure heat conduction in the sample holder of the closed-cycle cryostat, and the spectral acquisition time involved in recording the FLN spectrum. One of the four isomeric benzo[a]pyrene tetrols formed upon hydrolysis of benzo[a]pyrene-DNA adducts was used as a test compound. The separation of these tetrols with reversed-phase LC requires an eluent with high water content. Optimal results were obtained with deposition on silica TLC plates and the use of glycerol in the sample holder with a spectral acquisition time of 1 min. Under these conditions the detection limit is 30 fmol at 355 nm excitation. To improve the between-days fluctuation of the FLNS signal intensities, several compounds with a pyrene chromophore were tested as reference compounds. The use of 1-methoxypyrene as internal reference reduced the standard deviations 2-3-fold, viz. to less than 15% in FLN peak area. This indicates that the fluctuations are caused by experimental parameters, and not by the FLN process itself. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 16 条
[1]   FLUORESCENCE ENHANCEMENT OF POLYCYCLIC AROMATIC-HYDROCARBONS SEPARATED ON SILICA-GEL HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY PLATES [J].
HO, SSJ ;
BUTLER, HT ;
POOLE, CF .
JOURNAL OF CHROMATOGRAPHY, 1983, 281 (DEC) :330-339
[2]   COUPLING OF NARROW-BORE LIQUID-CHROMATOGRAPHY TO THIN-LAYER CHROMATOGRAPHY .2. APPLICATION OF FLUORESCENCE-BASED SPECTROSCOPIC TECHNIQUES FOR OFF-LINE DETECTION [J].
HOFSTRAAT, JW ;
ENGELSMA, M ;
VANDENESSE, RJ ;
BRINKMAN, UAT ;
GOOIJER, C ;
VELTHORST, NH .
ANALYTICA CHIMICA ACTA, 1987, 193 :193-207
[3]   COUPLING OF NARROW-BORE LIQUID-CHROMATOGRAPHY TO THIN-LAYER CHROMATOGRAPHY .1. INTERFACING [J].
HOFSTRAAT, JW ;
ENGELSMA, M ;
VANDENESSE, RJ ;
GOOIJER, C ;
VELTHORST, NH ;
BRINKMAN, UAT .
ANALYTICA CHIMICA ACTA, 1986, 186 :247-259
[4]   FLUORESCENCE LINE NARROWING - A HIGH-RESOLUTION WINDOW ON DNA AND PROTEIN DAMAGE FROM CHEMICAL CARCINOGENS [J].
JANKOWIAK, R ;
SMALL, GJ .
CHEMICAL RESEARCH IN TOXICOLOGY, 1991, 4 (03) :256-269
[5]   IDENTIFICATION OF STEREOISOMERIC BENZO[A]PYRENE TETROLS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED SEMI-ON-LINE TO FLUORESCENCE LINE-NARROWING SPECTROSCOPY [J].
KOK, SJ ;
POSTHUMUS, R ;
BAKKER, I ;
GOOIJER, C ;
BRINKMAN, UAT ;
VELTHORST, NH .
ANALYTICA CHIMICA ACTA, 1995, 303 (01) :3-10
[6]   SPECTROSCOPIC STUDIES OF PYRENE AT SILICA INTERFACES [J].
LOCHMULLER, CH ;
WENZEL, TJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (10) :4230-4235
[7]   Coupling protocol for thin layer chromatography matrix-assisted laser desorption ionization [J].
Mehl, JT ;
Gusev, AI ;
Hercules, DM .
CHROMATOGRAPHIA, 1997, 46 (7-8) :358-364
[8]   Direct quantitative analysis from thin-layer chromatography plates using matrix-assisted laser desorption/ionization mass spectrometry [J].
Nicola, AJ ;
Gusev, AI ;
Hercules, DM .
APPLIED SPECTROSCOPY, 1996, 50 (12) :1479-1482
[9]  
PERSONOV RI, 1983, SPECTROSCOPY EXCITAT
[10]   SOME QUANTITATIVE ASPECTS OF SCANNING DENSITOMETRY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
POOLE, CF ;
CODDENS, ME ;
BUTLER, HT ;
SCHUETTE, SA ;
HO, SSJ ;
KHATIB, S ;
PIET, L ;
BROWN, KK .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (16) :2875-2926