A photo-cured coated-wire calcium ion selective electrode for use in flow injection potentiometry

被引:16
作者
Alexander, PW [1 ]
Dimitrakopoulos, T [1 ]
Hibbert, DB [1 ]
机构
[1] UNIV NEW S WALES,DEPT ANALYT CHEM,SYDNEY,NSW 2052,AUSTRALIA
基金
澳大利亚研究理事会;
关键词
calcium selective electrodes; flow injection potentiometry; multi-sensor mode; photo-cured membrane;
D O I
10.1016/S0039-9140(97)00011-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi-sensor cell containing a new photo-cured calcium ion selective electrode sensor is reported. Four membranes containing different components are prepared to determine the one with optimum selectivity and sensitivity. This is shown to consist of the N,N,N',N'-tetracyclohexyl-3-oxapentanediamide ligand (ETH 129) as the ionophore, 2-nitrophenyl octyl ether as the plasticiser and tetradodecyl ammonium tetrakis(4-chlorophenyl) berate as the lipophilic additive. The photo-curing process is applied after coating a thin membrane on a silver wire as substrate transducer to produce the calcium sensor. The curing process is demonstrated to be faster (1 min) than previous methods and does not require a nitrogen atmosphere for reproducible production of membrane response characteristics. Four sensors constructed with the identical optimum membrane are shown to function reproducibly in a multi-sensor flow-through cell using the steady-state mode of flow measurement, and an average calibration slope of 28.5 +/- 0.4 mV change per activity decade is observed over a log-linear concentration range between 0.01 and 10 mM. The sensor is also shown to respond to changes in pH. Hence, in the flow injection potentiometric mode, a constant carrier buffer composition of pH 8.3 is required for accurate potentiometric calcium determinations. The sensor is used to determine calcium in water samples by flow injection potentiometry. The accuracy of the electrode determination relative to atomic absorption spectroscopy was in the range 5-9% for three different water samples. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1397 / 1405
页数:9
相关论文
共 28 条
[1]  
Alexander PW, 1996, FIELD ANAL CHEM TECH, V1, P31
[2]   Field-portable flow-injection analysers for monitoring of air and water pollution [J].
Alexander, PW ;
DiBenedetto, LT ;
Dimitrakopoulos, T ;
Hibbert, DB ;
Ngila, JC ;
Sequeira, M ;
Shiels, D .
TALANTA, 1996, 43 (06) :915-925
[3]  
ALEXANDER PW, 1991, Patent No. 7728
[4]  
BATES RG, 1973, DETERMINATION PH THE, P330
[5]   PHOTOCURABLE POLYMER MATRICES FOR POTASSIUM-SENSITIVE ION-SELECTIVE ELECTRODE MEMBRANES [J].
BRATOV, A ;
ABRAMOVA, N ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S ;
BARTROLI, J .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3589-3595
[6]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .2. A CALCIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1985, 177 :239-242
[7]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .3. A POTASSIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1988, 204 (1-2) :329-332
[8]   PHOTOCURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES [J].
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :403-406
[9]  
CATTRALL RW, 1984, ION SEL ELECTRODE R, V6, P125
[10]  
DELMUNDO FR, 1989, ELECTROANAL, V1, P179