Validity of the uniform mixing assumption: Determining human exposure to environmental tobacco smoke

被引:31
作者
Klepeis, NE [1 ]
机构
[1] Univ Calif Berkeley, Sch Publ Hlth, Berkeley, CA 94720 USA
关键词
mixing of pollutants; ideal mixing; uniform mixing; environmental tobacco smoke; the mass balance equation; exposure assessment; exposure modeling;
D O I
10.2307/3434428
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When using the mass balance equation to model indoor air quality, the primary assumption is that of uniform mixing. Different points in a single compartment are assumed to have the same instantaneous pollutant concentrations as all other points. Although such an assumption may be unrealistic, under certain conditions predictions (or measurements) of exposures at single points in a room are still within acceptable limits of error (e.g., 10%). in this article, three studies of the mixing of environmental tobacco smoke (ETS) pollutants are reviewed, and data from several other ETS field studies are presented. Under typical conditions for both short sources (e.g., 10 min) and the continuous sources of ETS in smoking lounges, I find that average exposure concentrations for a single point in a room represent the average exposure across all points in the room within 10% for averaging times ranging from 12 to 80 min. I present a method for determining theoretical estimates of acceptable averaging limes for a continuous point source.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 14 条
[1]   MIXING OF A POINT-SOURCE POLLUTANT BY NATURAL-CONVECTION FLOW WITHIN A ROOM [J].
BAUGHMAN, AV ;
GADGIL, AJ ;
NAZAROFF, WW .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :114-122
[2]   MIXING OF A POINT-SOURCE INDOOR POLLUTANT BY FORCED-CONVECTION [J].
DRESCHER, AC ;
LOBASCIO, C ;
GADGIL, AJ ;
NAZAROFF, WW .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1995, 5 (03) :204-214
[3]   Modeling indoor air concentrations near emission sources in imperfectly mixed rooms [J].
Furtaw, EJ ;
Pandian, MD ;
Nelson, DR ;
Behar, JV .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (09) :861-868
[4]   AIR MOVEMENT IN BUILDINGS USING COMPUTATIONAL FLUID-DYNAMICS [J].
HAGHIGHAT, F ;
JIANG, Z ;
WANG, JCY ;
ALLARD, F .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (02) :84-92
[5]  
HAMMOND S, COMMUNICATION
[6]   A multiple-smoker model for predicting indoor air quality in public lounges [J].
Klepeis, NE ;
Ott, WR ;
Switzer, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (09) :2813-2820
[7]   An introduction to the indirect exposure assessment approach: Modeling human exposure using microenvironmental measurements and the recent National Human Activity Pattern Survey [J].
Klepeis, NE .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :365-374
[8]  
MAGE DT, 1996, STP ASTM, V1287, P263
[9]   Particle concentrations inside a tavern before and after prohibition of smoking: Evaluating the performance of an indoor air quality model [J].
Ott, W ;
Switzer, P ;
Robinson, J .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (12) :1120-1134
[10]  
Ott W., 1992, J EXPO ANAL ENV EPID, V2, P175