A prospective, within-patient comparison between metal butterfly needles and Teflon cannulae in subcutaneous infusion of drugs to terminally ill hospice patients

被引:13
作者
Ross, JR
Saunders, Y
Cochrane, M
Zeppetella, G
机构
[1] St Josephs Hospice, CPCT, London E8 4SA, England
[2] Royal Marsden Hosp, London SW3 6JJ, England
关键词
metal butterfly needle; subcutaneous; Teflon cannula; terminal care;
D O I
10.1191/0269216302pm471oa
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
We performed a prospective study of hospice in-patients requiring a syringe driver (SD), to determine the site duration and tolerability of metal butterfly needles compared to Teflon cannulae. Using patients as their own control, prescribed medications were divided equally between two SDs (Graseby MS16a), for delivery over 24 h. A butterfly infusion (Flosafer(TM), 25 gauge) was connected to one SD and a Teflon cannula (Abbocath -T, 24 gauge), to the second. These were inserted subcutaneously (sc) on opposite sides of the body at comparable sites; oedematous, broken or painful sites were excluded. SD sites were examined at 4-hourly intervals. The study was terminated when both devices had required resiting. Needle and cannula times were compared using the Wilcoxon signed rank test. Thirty patients entered the study, 13 males and 17 females, mean age (standard deviation): 70 (11) years. Thirteen patients completed the study. Nine patients died and eight patients discontinued the study before both needle and cannula had been resited. All 30 patients are included in the analysis. The time from insertion to resiting of the cannula was significantly longer than the needle: P < 0.0002, median (range) 93.5 (22.8-263.5) h versus 42.8 (7.5-162.3) h, respectively. The cost of the needle versus cannula is £1.93 versus £2.51, respectively. Teflon cannulae have a median life span twice that of metal butterfly needles and are a cost-effective alternative for administration of medications by sc infusion in terminally ill patients.
引用
收藏
页码:13 / 16
页数:4
相关论文
共 9 条
[1]  
Currow David, 1994, Palliative Medicine, V8, P333, DOI 10.1177/026921639400800410
[2]  
Dawkins L, 2000, Int J Palliat Nurs, V6, P110
[3]  
JOHNSON I, 1992, Palliative Medicine, V6, P125, DOI 10.1177/026921639200600206
[4]  
LICHTER I, 1995, NEW ZEAL MED J, V108, P224
[5]   A PROSPECTIVE COMPARISON STUDY BETWEEN A BUTTERFLY NEEDLE AND A TEFLON CANNULA FOR SUBCUTANEOUS NARCOTIC ADMINISTRATION [J].
MACMILLAN, K ;
BRUERA, E ;
KUEHN, N ;
SELMSER, P ;
MACMILLAN, A .
JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 1994, 9 (02) :82-84
[6]   Drugs and syringe drivers: a survey of adult specialist palliative care practice in the United Kingdom and Eire [J].
O'Doherty, CA ;
Hall, EJ ;
Schofield, L ;
Zeppetella, G .
PALLIATIVE MEDICINE, 2001, 15 (02) :149-154
[7]  
ROBERTS CJC, 1998, OXFORD TXB PALLIATIV
[8]  
VENTAFRIDDA V, 1986, PAIN CLINIC, V1, P47
[9]   COMPARISON OF TEFLON CANNULAS AND METAL NEEDLES FOR SUBCUTANEOUS INFUSION IN TERMINAL CARE - A PILOT-STUDY [J].
YOUSSEF, MS ;
ATKINSON, RE .