The cochlear implant electrode-pitch function

被引:53
作者
Baumann, U
Nobbe, A
机构
[1] Univ Munich, Dept Otorhinolaryngol, D-81377 Munich, Germany
[2] Med El GmbH, A-6020 Innsbruck, Austria
[3] Univ Munich, ENT Dept, Munich, Germany
关键词
cochlear implant; electric hearing; frequency-place function; pitch sensation;
D O I
10.1016/j.heares.2005.12.010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The cochlear frequency-place function in normal hearing cars has been found to be an exponential relationship in a wide variety of species [D.D. Greenwood, J. Acoust. Soc. Am. 87 (1990) 2592-2605]. Although it seems reasonable to assume a similar function for electrical stimulation by means of an intra-cochlear electrode array, the exact frequency-place function for this special type of stimulation needs to be investigated. Six users of the MED-EL COMBI 40+ cochlear implant device with moderate to profound hearing loss between 125 and 1000 Hz in the non-implanted ear took part in a binaural pitch adjustment experiment. The COMBI 40+ electrode array provides a deep insertion into the scala tympani and a wide spatial separation between the stimulating electrodes. Insertion depth was controlled by Stenver's view plain radiographs and the insertion angle was estimated. The task of the subjects was to adjust the frequency of a sinusoid presented in the non-implanted ear by means of an adjusting knob until they perceived the same pitch as was elicited by a reference stimulus in the implanted ear. The results show adjustments corresponding to electrode positions along the cochlea, with the exception of the two most apical electrodes for most of the Subjects. Pitch increased in an orderly fashion with an average of 98 Hz per electrode separation (40 Hz/mm). In contrast to the exponential predictions according to [D.D. Greenwood, J. Acoust. Soc. Am. 87 (1990) 2592-2605] for normal hearing, the average electrode-pitch function shows a linear relationship. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 42
页数:9
相关论文
共 20 条
[1]   Pulse rate discrimination with deeply inserted electrode arrays [J].
Baumann, U ;
Nobbe, A .
HEARING RESEARCH, 2004, 196 (1-2) :49-57
[2]   Pitch ranking with deeply inserted electrode arrays [J].
Baumann, U ;
Nobbe, A .
EAR AND HEARING, 2004, 25 (03) :275-283
[3]  
BOEX C, 2006, IN PRESS J ASS RES O
[4]  
Cohen LT, 1996, AM J OTOL, V17, P859
[5]   THE PITCH OF ELECTRICALLY PRESENTED SINUSOIDS [J].
DORMAN, MF ;
SMITH, M ;
SMITH, L ;
PARKIN, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (03) :1677-1679
[6]   CRITICAL BANDWIDTH AND FREQUENCY COORDINATES OF BASILAR MEMBRANE [J].
GREENWOOD, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1961, 33 (10) :1344-&
[7]   A COCHLEAR FREQUENCY-POSITION FUNCTION FOR SEVERAL SPECIES - 29 YEARS LATER [J].
GREENWOOD, DD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (06) :2592-2605
[8]   Deep electrode insertion in cochlear implants:: Apical morphology, electrodes and speech perception results [J].
Hochmair, I ;
Arnold, W ;
Nopp, P ;
Jolly, C ;
Müller, J ;
Roland, P .
ACTA OTO-LARYNGOLOGICA, 2003, 123 (05) :612-617
[9]   A test for the diagnosis of dead regions in the cochlea [J].
Moore, BCJ ;
Huss, M ;
Vickers, DA ;
Glasberg, BR ;
Alcántara, JI .
BRITISH JOURNAL OF AUDIOLOGY, 2000, 34 (04) :205-224
[10]   The use of psychophysical tuning curves to explore dead regions in the cochlea [J].
Moore, BCJ ;
Alcántara, JI .
EAR AND HEARING, 2001, 22 (04) :268-278