摘要
Considerations of weight factors and far-end faults in the directional overcurrent relay coordination problem formulation do not affect the optimal solution. This paper investigates this viewpoint and verifies that indeed by such an approach the optimality is not lost. But, this study reveals that in doing so, the coordination quality is sacrificed to some extent. It is also observed that if all remaining valid constraints (after relaxing few constraints based on the back-up coordination philosophy and strength of fault level generated) are considered and if the objective function is changed to running sum of all violating constraints, all valid considered constraints are satisfied. This study is done by simultaneously optimizing all settings in nonlinear environment by Sequential Quadratic Programming method using Matlab Toolbox. The results of the analysis on a sample 6-bus and IEEE 30-bus systems are presented in this paper.
引用
收藏
页码:1176 / 1182
页数:7
相关论文
共 35 条
[1]
An adaptive protection scheme for optimal coordination of overcurrent relays [J].
Abdelaziz, AY ;
Talaat, HEA ;
Nosseir, AI ;
Hajjar, AA .
ELECTRIC POWER SYSTEMS RESEARCH, 2002, 61 (01) :1-9
[2]
ABDELAZIZ AY, 1999, P 3 CIGRE REG C AR C
[3]
A new optimal approach for coordination of overcurrent relays in interconnected power systems [J].
Abyaneh, HA ;
Al-Dabbagh, M ;
Karegar, HK ;
Sadeghi, SHH ;
Khan, RAJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (02) :430-435
[4]
ABYANEH HA, 2002, P AUSTR U POW ENG C
[6]
Albrecht RE, 1964, IEEE T POWER APPARAT, V83, P402, DOI DOI 10.1109/TPAS.1964.4766018
[8]
Time-Overcurrent Relay Coordination: A Review [J].
Birla, Dinesh ;
Maheshwari, Rudra Prakash ;
Gupta, Hari Om .
INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2005, 2 (02)
[9]
Braga A. S., 1996, P IEEE MELECON C, V3, P1535
[10]
A PERSONAL-COMPUTER APPROACH TO OVERCURRENT PROTECTIVE DEVICE COORDINATION [J].
BROWN, KA ;
PARKER, JM .
IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (02) :509-513