Virtual CT intravascular endoscopy of the aorta: Pierced surface and floating shape thresholding artifacts

被引:12
作者
Neri, E [1 ]
Caramella, D [1 ]
Falaschi, F [1 ]
Sbragia, P [1 ]
Vignali, C [1 ]
Laiolo, E [1 ]
Viviani, A [1 ]
Bartolozzi, C [1 ]
机构
[1] Univ Pisa, Dept Oncol Diagnost & Intervent Radiol, I-56100 Pisa, Italy
关键词
aorta; CT; aortography; virtual; computed tomography (CT); image display and recording; three-dimensional;
D O I
10.1148/radiology.212.1.r99jl03276
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two types of artifacts may appear in virtual computed tomographic endoscopic views of the aorta rendered at different threshold levels: pierced surface and floating shape artifacts. A positive correlation was found between mean attenuation of the aorta and the threshold levels at which these artifacts appeared. The correlation was statistically significant (0.71 less than or equal to r less than or equal to 0.86) for floating shape. An artifact-free threshold range can be predicted on the basis of aortic enhancement.
引用
收藏
页码:276 / 279
页数:4
相关论文
共 18 条
[1]   CT in vascular pathologies [J].
Bartolozzi, C ;
Neri, E ;
Caramella, D .
EUROPEAN RADIOLOGY, 1998, 8 (05) :679-684
[2]   Virtual tracheo-bronchial endoscopy: Educational and diagnostic value [J].
Buthiau, D ;
Antoine, E ;
Piette, JC ;
Nizri, D ;
Baldeyrou, P ;
Khayat, D .
SURGICAL AND RADIOLOGIC ANATOMY, 1996, 18 (02) :125-131
[3]   Human aorta: Preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets [J].
Davis, CP ;
Ladd, ME ;
Romanowski, BJ ;
Wildermuth, S ;
Knoplioch, JF ;
Debatin, JF .
RADIOLOGY, 1996, 199 (01) :37-40
[4]   Virtual intravascular endoscopy in the renal arteries: A new way of reading 3-D MR-angiography datasets. [J].
Davis, CP ;
Ladd, ME ;
Gohde, SC ;
Pfammatter, T ;
Fass, L ;
Debatin, JF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (03) :257-263
[5]  
DUBNO B, 1997, RADIOLOGY, V205, P197
[6]   Three-dimensional computed tomography of the reconstructed lower urinary tract: technique and findings [J].
Frank, R ;
Stenzl, A ;
Frede, T ;
Eder, R ;
Recheis, W ;
Knapp, R ;
Bartsch, G ;
zur Nedden, D .
EUROPEAN RADIOLOGY, 1998, 8 (04) :657-663
[7]   Virtual otoscopy [J].
Frankenthaler, R ;
Moharir, V ;
Kikinis, R ;
van Kipshagen, P ;
Jolesz, F ;
Umans, C ;
Fried, MP .
OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1998, 31 (02) :383-+
[8]   Colorectal polyp detection with CT colography: Two- versus three-dimensional techniques - Work in progress [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ehman, RL ;
Ilstrup, DM .
RADIOLOGY, 1996, 200 (01) :49-54
[9]  
Hayashi Hiromitsu, 1996, Nippon Acta Radiologica, V56, P135
[10]   Thoracic aortic aneurysm and aortic dissection: New endoscopic mode for three-dimensional CT display of aorta [J].
Kimura, F ;
Shen, Y ;
Date, S ;
Azemoto, S ;
Mochizuki, T .
RADIOLOGY, 1996, 198 (02) :573-578