Robust and sensitive iTRAQ quantification on an LTQ orbitrap mass spectrometer

被引:195
作者
Bantscheff, Marcus [1 ]
Boesche, Markus [1 ]
Eberhard, Dirk [1 ]
Matthieson, Toby [1 ]
Sweetman, Gavain [1 ]
Kuster, Bernhard [1 ]
机构
[1] Cellzome AG, D-69117 Heidelberg, Germany
关键词
D O I
10.1074/mcp.M800029-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Isobaric stable isotope tagging reagents such as tandem mass tags or isobaric tags for relative and absolute quantification enable multiplexed quantification of peptides via reporter ion signals in the low mass range of tandem mass spectra. Until recently, the poor recovery of low mass fragments observed in tandem mass spectra acquired on ion trap mass spectrometers precluded the use of these reagents on this widely available instrument platform. The Pulsed Q Dissociation (PQD) technique allows negotiating this limitation but suffers from poor fragmentation efficiency, which has raised doubts in the community as to its practical utility. Here we show that by carefully optimizing instrument parameters such as collision energy, activation Q, delay time, ion isolation width, number of microscans, and number of trapped ions, low m/z fragment ion intensities can be generated that enable accurate peptide quantification at the 100 amol level. Side by side comparison of PQD on an LTQ Orbitrap with CID on a five-year old Q-Tof Ultima using complex protein digests shows that whereas precision of quantification of 10-15% can be achieved by both approaches, PQD quantifies twice as many proteins. PQD on an LTQ Orbitrap also outperforms "higher energy collision induced dissociation" on the same instrument using the recently introduced octapole collision cell in terms of lower limit of quantification. Finally, we demonstrate the significant analytical potential of iTRAQ quantification using PQD on an LTQ Orbitrap by quantitatively measuring the kinase interaction profile of the small molecule drug imatinib in K-562 cells. This article gives practical guidance for the implementation of PQD, discusses its merits, and for the first time, compares its performance to higher energy collision-induced dissociation.
引用
收藏
页码:1702 / 1713
页数:12
相关论文
共 22 条
[1]   Quantitative mass spectrometry in proteomics: a critical review [J].
Bantscheff, Marcus ;
Schirle, Markus ;
Sweetman, Gavain ;
Rick, Jens ;
Kuster, Bernhard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (04) :1017-1031
[2]   Quantitative chemical proteomics reveals mechanisms of action of clinical ABL kinase inhibitors [J].
Bantscheff, Marcus ;
Eberhard, Dirk ;
Abraham, Yann ;
Bastuck, Sonja ;
Boesche, Markus ;
Hobson, Scott ;
Mathieson, Toby ;
Perrin, Jessica ;
Raida, Manfred ;
Rau, Christina ;
Reader, Valerie ;
Sweetman, Gavain ;
Bauer, Andreas ;
Bouwmeester, Tewis ;
Hopf, Carsten ;
Kruse, Ulrich ;
Neubauer, Gitte ;
Ramsden, Nigel ;
Rick, Jens ;
Kuster, Bernhard ;
Drewes, Gerard .
NATURE BIOTECHNOLOGY, 2007, 25 (09) :1035-1044
[3]   High amplitude short time excitation: A method to form and detect low mass product ions in a quadrupole ion trap mass spectrometer [J].
Cunningham, C ;
Glish, GL ;
Burinsky, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (01) :81-84
[4]   Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry [J].
Elias, Joshua E. ;
Gygi, Steven P. .
NATURE METHODS, 2007, 4 (03) :207-214
[5]   Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS [J].
Gerber, SA ;
Rush, J ;
Stemman, O ;
Kirschner, MW ;
Gygi, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (12) :6940-6945
[6]   iTRAQ reagent-based quantitative proteomic analysis on a linear ion trap mass spectrometer [J].
Griffin, Timothy J. ;
Xie, Hongwei ;
Bandhakavi, Sricharan ;
Popko, Jonathan ;
Mohan, Archana ;
Carlis, John V. ;
Higgins, LeeAnn .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (11) :4200-4209
[7]   Quantitative analysis of complex protein mixtures using isotope-coded affinity tags [J].
Gygi, SP ;
Rist, B ;
Gerber, SA ;
Turecek, F ;
Gelb, MH ;
Aebersold, R .
NATURE BIOTECHNOLOGY, 1999, 17 (10) :994-999
[8]   Automation of nanoscale microcapillary liquid chromatography-tandem mass spectromentry with a vented column [J].
Licklider, LJ ;
Thoreen, CC ;
Peng, JM ;
Gygi, SP .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3076-3083
[9]   Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer [J].
Makarov, A ;
Denisov, E ;
Kholomeev, A ;
Baischun, W ;
Lange, O ;
Strupat, K ;
Horning, S .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2113-2120
[10]   Identification of carbonylated proteins from enriched rat skeletal muscle mitochondria using affinity chromatography-stable isotope labeling and tandem mass spectrometry [J].
Meany, Danni L. ;
Xie, Hongwei ;
Thompson, LaDora V. ;
Arriaga, Edgar A. ;
Griffin, Timothy J. .
PROTEOMICS, 2007, 7 (07) :1150-1163