Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system

被引:60
作者
Brock, Timothy M. [1 ]
Sidaginamale, Raghavendra [1 ]
Rushton, Steven [1 ]
Nargol, Antoni V. F. [2 ]
Bowsher, John G. [3 ]
Savisaar, Christina [3 ]
Joyce, Tom J. [1 ]
Deehan, David J. [1 ]
Lord, James K. [4 ]
Langton, David J. [5 ]
机构
[1] Newcastle Univ, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Hosp North Tees, Dept Orthopaed, North Tees, England
[3] US FDA, Silver Spring, MD USA
[4] Calif Polytech State Univ San Luis Obispo, Biomed & Gen Engn, San Luis Obispo, CA 93407 USA
[5] Univ Hosp North Tees, North Tees Explant Ctr, North Tees, England
关键词
metal-on-metal; taper-junction; arthroplasty; explant analysis; FAILURE RATES; REPLACEMENT; TOPOGRAPHY; JUNCTION;
D O I
10.1002/jor.22970
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Taper wear at the head-neck junction is a possible cause of early failure in large head metal-on-metal (LH-MoM) hip replacements. We hypothesized that: (i) taper wear may be more pronounced in certain product designs; and (ii) an increased abductor moment arm may be protective. The tapers of 104 explanted LH-MoM hip replacements revised for adverse reaction to metal debris (ARMD) from a single manufacturer were analyzed for linear and volumetric wear using a co-ordinate measuring machine. The mated stem was a shorter 12/14, threaded trunnion (n=72) or a longer, smooth 11/13 trunnion (n=32). The abductor moment arm was calculated from pre-revision radiographs. Independent predictors of linear and volumetric wear included taper angle, stem type, and the horizontal moment arm. Tapers mated with the threaded 12/14 trunnion had significantly higher rates of volumetric wear (0.402mm(3)/yr vs. 0.123mm(3)/yr [t=-2.145, p=0.035]). There was a trend to larger abductor moment arms being protective (p=0.055). Design variation appears to play an important role in taper-trunnion junction failure. We recommend that surgeons bear these findings in mind when considering the use of a short, threaded trunnion with a cobalt-chromium head. (c) 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1868-1874, 2015.
引用
收藏
页码:1868 / 1874
页数:7
相关论文
共 16 条
[1]
High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS [J].
Bolland, B. J. R. F. ;
Culliford, D. J. ;
Langton, D. J. ;
Millington, J. P. S. ;
Arden, N. K. ;
Latham, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :608-615
[2]
Total hip arthroplasty head-neck contact mechanics: A stochastic investigation of key parameters [J].
Donaldson, Finn E. ;
Coburn, James C. ;
Siegel, Karen Lohmann .
JOURNAL OF BIOMECHANICS, 2014, 47 (07) :1634-1641
[3]
Practical considerations for volumetric wear analysis of explanted hip arthroplasties [J].
Langton, D. J. ;
Sidaginamale, R. P. ;
Holland, J. P. ;
Deehan, D. ;
Joyce, T. J. ;
Nargol, A. V. F. ;
Meek, R. D. ;
Lord, J. K. .
BONE & JOINT RESEARCH, 2014, 3 (03) :60-68
[4]
Taper junction failure in large-diameter metal-on-metal bearings [J].
Langton, D. J. ;
Sidaginamale, R. ;
Lord, J. K. ;
Nargol, A. V. F. ;
Joyce, T. J. .
BONE & JOINT RESEARCH, 2012, 1 (04) :56-63
[5]
Accelerating failure rate of the ASR total hip replacement [J].
Langton, D. J. ;
Jameson, S. S. ;
Joyce, T. J. ;
Gandhi, J. N. ;
Sidaginamale, R. ;
Mereddy, P. ;
Lord, J. ;
Nargol, A. V. F. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (08) :1011-1016
[6]
Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses [J].
Lord, J. K. ;
Langton, D. J. ;
Nargol, A. V. F. ;
Joyce, T. J. .
WEAR, 2011, 272 (01) :79-87
[7]
Material Loss at the Taper Junction of Retrieved Large Head Metal-on-Metal Total Hip Replacements [J].
Matthies, Ashley K. ;
Racasan, Radu ;
Bills, Paul ;
Blunt, Liam ;
Cro, Suzie ;
Panagiotidou, Anna ;
Blunn, Gordon ;
Skinner, John ;
Hart, Alister J. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (11) :1677-1685
[8]
EFFECT OF FEMORAL OFFSET ON RANGE OF MOTION AND ABDUCTOR MUSCLE STRENGTH AFTER TOTAL HIP-ARTHROPLASTY [J].
MCGRORY, BJ ;
MORREY, BF ;
CAHALAN, TD ;
AN, KN ;
CABANELA, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (06) :865-869
[9]
Why does titanium alloy wear cobalt chrome alloy despite lower bulk hardness: A nanoindentation study? [J].
Moharrami, N. ;
Langton, D. J. ;
Sayginer, O. ;
Bull, S. J. .
THIN SOLID FILMS, 2013, 549 :79-86
[10]
Variations in the Trunnion Surface Topography Between Different Commercially Available Hip Replacement Stems [J].
Munir, Selin ;
Walter, William L. ;
Walsh, William Robert .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (01) :98-105