Incorporation of a DNAzyme into Au-coated nanocapillary array membranes with an internal standard for Pb(II) sensing

被引:52
作者
Wernette, DP
Swearingen, CB
Cropek, DM
Lu, Y
Sweedler, JV
Bohn, PW
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[3] Construct Engn Res Lab, Champaign, IL 61822 USA
关键词
D O I
10.1039/b510071b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Pb(II)-specific DNAzyme has been successfully incorporated into Au-coated polycarbonate track-etched (PCTE) nanocapillary array membranes (NCAMs) by thiol-gold immobilization. Incorporation of the DNAzyme into the membrane provides a substrate-bound sensor using a novel internal control methodology for fluorescence-based detection of Pb(II). A non-cleavable substrate strand, identical to the cleavable DNAzyme substrate strand except the RNA-base is replaced by the corresponding DNA-base, is used for ratiometric comparison of intensities. The cleavable substrate strand is labeled with fluorescein, and the non-cleavable strand is labeled with a red fluorophore (Cy5 or Alexa 546) for detection after release from the membrane surface. This internal standard based ratiometric method allows for real-time monitoring of Pb(II)-induced cleavage, as well as standardizing variations in substrate size, solution detection volume, and monolayer density. The result is a Pb(II)-sensing structure that can be stored in a prepared state for 30 days, regenerated after reaction, and detect Pb(II) concentrations as low as 17 nM (3.5 ppb).
引用
收藏
页码:41 / 47
页数:7
相关论文
共 46 条
[1]   Structure-switching allosteric deoxyribozymes [J].
Achenbach, JC ;
Nutiu, R ;
Li, YF .
ANALYTICA CHIMICA ACTA, 2005, 534 (01) :41-51
[2]   Controlling the adsorption and reactivity of DNA on gold [J].
Aqua, T ;
Naaman, R ;
Daube, SS .
LANGMUIR, 2003, 19 (25) :10573-10580
[3]   Immunoassays for metal ions [J].
Blake, DA ;
Blake, RC ;
Khosraviani, M ;
Pavlov, AR .
ANALYTICA CHIMICA ACTA, 1998, 376 (01) :13-19
[4]  
Breaker R R, 1994, Chem Biol, V1, P223, DOI 10.1016/1074-5521(94)90014-0
[5]   Fluorescent sensors for Zn2+ based on a fluorescein platform:: Synthesis, properties and intracellular distribution [J].
Burdette, SC ;
Walkup, GK ;
Spingler, B ;
Tsien, RY ;
Lippard, SJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (32) :7831-7841
[6]  
Crowley K, 2002, ELECTROANAL, V14, P1077, DOI 10.1002/1521-4109(200208)14:15/16<1077::AID-ELAN1077>3.0.CO
[7]  
2-3
[8]   DESPERATELY SEEKING SENSORS [J].
CZARNIK, AW .
CHEMISTRY & BIOLOGY, 1995, 2 (07) :423-428
[9]   A selective, ratiometric fluorescent sensor for Pb2+ [J].
Deo, S ;
Godwin, HA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (01) :174-175
[10]   Determination of organic lead in soils and waters by hydride generation inductively coupled plasma atomic emission spectrometry [J].
Elfering, H ;
Andersson, JT ;
Poll, KG .
ANALYST, 1998, 123 (04) :669-674