Comparison between fast MR flow quntification in breathhold technique in ascending aorta and pulmonary trunc with right and left ventricular cine-MRI for the assessment of stroke volumes in healthy volunteers

被引:21
作者
Rominger, MB
Dinkel, HP
Bachmann, GF
机构
[1] Univ Marburg, Abt Strahlendiagnost, D-35043 Marburg, Germany
[2] Univ Giessen, Abt Diagnost Radiol, D-35390 Giessen, Germany
[3] Univ Bern, Kantonsspital, Bern, Switzerland
[4] Kerckhoff Klin GmbH, Diagnost Radiol, Bad Nauheim, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 02期
关键词
heart; MR; function; volume; cine study; rapid imaging; flow quantification;
D O I
10.1055/s-2002-20104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of accordance and reproducibility of the stroke volume assessment of fast flow measurement in breath-hold technique in the ascending aorta and pulmonary trunc with fast right (RV) and left ventricular (LV) cine-MRI. Material and Methods: The correlation an accordance of stroke volumes (SV) were evaluated by flow measurements in the ascending aorta and pulmonary trunc and RV and LV volumetric cine-MRI in 33 cardiac healthy volunteers, Interobserver and intraobserver variability of the different measurement methods and locations were checked in 10 cardiac healthy volunteers. Results: With respect to the early systolic flow and the extrapolation of the endiastolic flow rate the difference in SV was smaller than 1,5 ml/m(2) for all possible combinations. The interobserver and intraobserver variabilities of flow measurements were significantly lower by approximately a factor of 2.5 than those of RV and LV cine-MRI. Conclusion: The accordance of fast prospective triggered flow measurements in the ascending aorta and pulmonary trunc with RV and LV cine-MRI can be achieved with reasonable limits of agreement. Flow measurements are more reproducible than cine-MRI.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 13 条
[1]   Left-to-right cardiac shunts:: Comparison of measurements obtained with MR velocity mapping and with radionuclide angiography [J].
Arheden, H ;
Holmqvist, C ;
Thilen, U ;
Hanséus, K ;
Björkhem, G ;
Pahlm, O ;
Laurin, S ;
Ståhlberg, F .
RADIOLOGY, 1999, 211 (02) :453-458
[2]   BRONCHOPULMONARY ANASTOMOTIC AND NONCORONARY COLLATERAL BLOOD-FLOW IN HUMANS DURING CARDIOPULMONARY BYPASS [J].
BAILE, EM ;
LING, H ;
HEYWORTH, JR ;
HOGG, JC ;
PARE, PD .
CHEST, 1985, 87 (06) :749-754
[3]  
CUDKOWICZ L, 1979, PULMONARY VASCULAR D, P111
[4]   MAGNETIC-RESONANCE-IMAGING OF BLOOD-FLOW WITH A PHASE SUBTRACTION TECHNIQUE - INVITRO AND INVIVO VALIDATION [J].
EVANS, AJ ;
IWAI, F ;
GRIST, TA ;
SOSTMAN, HD ;
HEDLUND, LW ;
SPRITZER, CE ;
NEGROVILAR, R ;
BEAM, CA ;
PELC, NJ .
INVESTIGATIVE RADIOLOGY, 1993, 28 (02) :109-115
[5]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[6]   ASSESSMENT OF LEFT-TO-RIGHT INTRACARDIAC SHUNTING BY VELOCITY-ENCODED, PHASE-DIFFERENCE MAGNETIC-RESONANCE-IMAGING - A COMPARISON WITH OXIMETRIC AND INDICATOR DILUTION TECHNIQUES [J].
HUNDLEY, WG ;
LI, HF ;
LANGE, RA ;
PFEIFER, DP ;
MESHACK, BM ;
WILLARD, JE ;
LANDAU, C ;
WILLETT, D ;
HILLIS, LD ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (12) :2955-2960
[7]   Flow quantification of different cardiac shunts by using a new breath-hold, velocity-encoded, phase-difference magnetic resonance (MR) technique [J].
Kalden, P ;
Kreitner, KF ;
Voigtlander, T ;
Roberts, H ;
Roberts, T ;
Krummenauer, F ;
Becker, D ;
Wittlinger, T ;
Meyer, J ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (04) :378-382
[8]   CT ANGIOGRAPHY OF THE BRONCHIAL ARTERIES [J].
KAUCZOR, HU ;
CAGIL, H ;
FISCHER, B ;
SCHWICKERT, HC ;
MILDENBERGER, P .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (05) :477-479
[9]   RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION [J].
KONDO, C ;
CAPUTO, GR ;
SEMELKA, R ;
FOSTER, E ;
SHIMAKAWA, A ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :9-16
[10]  
Miller S, 1999, ROFO-FORTSCHR RONTG, V170, P47