Selective imaging of biofilms in porous media by NMR relaxation

被引:54
作者
Hoskins, BC
Fevang, L
Majors, PD
Sharma, MM
Georgiou, G
机构
[1] Univ Texas, Dept Petr & Geosyst Engn, Austin, TX 78712 USA
[2] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
关键词
biofilm; porous media; selective imaging; relaxation NMRI; image sorting;
D O I
10.1006/jmre.1999.1747
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nuclear magnetic resonance imaging (NMRI) techniques were employed to identify and selectively image biological films (biofilm) growing in aqueous systems. Biofilms are shown to affect both the longitudinal (T-1) and transverse (T-2) NMR relaxation time values of proximal water hydrogens. Results are shown for biofilm growth experiments performed in a transparent parallel-plate reactor. A comparison of biofilm distributions by both NMR and optical imaging yielded general agreement for both an open-flow system and an idealized porous system (the reactor without and with packed glass beads, respectively). The selective imaging of biofilm by relaxation NMRI is dependent upon the resolution of relaxation times for the fluid phases, dynamic range, and signal-to-noise ratio, For open-flow systems, the use of a rapid and quantitative T-2-sorted NMRI technique was preferred. For porous systems where T-2 values are generally more similar, a T-1-weighted technique was preferred. (C) 1999 Academic Press.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 22 条
[1]   IMPORTANCE OF CLASSICAL DIFFUSION IN NMR-STUDIES OF WATER IN BIOLOGICAL CELLS [J].
BROWNSTEIN, KR ;
TARR, CE .
PHYSICAL REVIEW A, 1979, 19 (06) :2446-2453
[2]  
Callaghan P.T., 1991, Principles of nuclear magnetic resonance microscopy, V1st
[3]   MODELING TRANSPORT AND BIODEGRADATION OF BENZENE AND TOLUENE IN SANDY AQUIFER MATERIAL - COMPARISONS WITH EXPERIMENTAL MEASUREMENTS [J].
CHEN, YM ;
ABRIOLA, LM ;
ALVAREZ, PJJ ;
ANID, PJ ;
VOGEL, TM .
WATER RESOURCES RESEARCH, 1992, 28 (07) :1833-1847
[4]   MULTIEXPONENTIAL ANALYSIS OF RELAXATION DECAYS [J].
CLAYDEN, NJ ;
HESLER, BD .
JOURNAL OF MAGNETIC RESONANCE, 1992, 98 (02) :271-282
[5]   INFLUENCE OF BIOFILM ACCUMULATION ON POROUS-MEDIA HYDRODYNAMICS [J].
CUNNINGHAM, AB ;
CHARACKLIS, WG ;
ABEDEEN, F ;
CRAWFORD, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (07) :1305-1311
[6]   SPIN WARP NMR IMAGING AND APPLICATIONS TO HUMAN WHOLE-BODY IMAGING [J].
EDELSTEIN, WA ;
HUTCHISON, JMS ;
JOHNSON, G ;
REDPATH, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04) :751-756
[7]  
FARRAR TC, 1971, PULSE FOURIER TRANSF
[8]  
FEVANG L, 1997, THESIS U TEXAS AUSTI
[9]  
Fukushima E., 1981, EXPT PULSE NMR
[10]  
KENYON WE, 1992, NUCL GEOPHYS, V6, P153