Intraparticle flow and plate height effects in liquid chromatography stationary phases

被引:12
作者
Hamaker, KH [1 ]
Ladisch, MR [1 ]
机构
[1] PURDUE UNIV,DEPT AGR & BIOL ENGN,RENEWABLE RESOURCES ENGN LAB,W LAFAYETTE,IN 47907
来源
SEPARATION AND PURIFICATION METHODS | 1996年 / 25卷 / 01期
关键词
D O I
10.1080/03602549608006626
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Velocity independent plate heights were apparently first recognized for hydrodynamic chromatography columns, packed with nonporous, 115 micron glass beads which were run at reduced mobile phase velocities of 10 to 10,000. Hydrodynamic chromatography separates based on the tendency of small molecules (or particles) to associate with slower moving fluid streamlines near the surfaces of particles, compared to larger molecules which seek faster streamlines. Consequently, the larger molecules elute first. Velocity independent plate heights in liquid chromatography have also been observed for nonadsorbed solutes in particulate and fibrous stationary phases. These stationary phases have pores which exceed 10(-4) to 10(-5) cm in dimension. The flat plate height is attributed to flow in the channels formed by these large intraparticle spaces. The development of plate height expressions which represent dispersion at interstitial velocities above 10 cm/min are discussed. Explanations of the uncoupling of dispersion from eluent flow rate in continuous stationary phases, membranes, and gigaporous particles is shown to have their origins in the studies of distribution of particles and molecules in hydrodynamic chromatography columns, and to be adequately described by modifications of the van Deemter equation.
引用
收藏
页码:47 / 83
页数:37
相关论文
共 47 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
[Anonymous], [No title captured]
[3]  
CARTA G, 1992, SEPAR TECHNOL, V2, P62, DOI DOI 10.1016/0956-9618(92)80008-2
[4]   PREPARATION AND EVALUATION OF INORGANIC ANION-EXCHANGE SORBENTS NOT BASED ON SILICA [J].
CHICZ, RM ;
SHI, Z ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :121-130
[5]   DIFFUSION OF HUMIC-ACID IN DILUTE AQUEOUS-SOLUTION [J].
CORNEL, PK ;
SUMMERS, RS ;
ROBERTS, PV .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1986, 110 (01) :149-164
[6]   PERFORMANCE OF PACKINGS IN HIGH-SPEED LIQUID CHROMATOGRAPHY .2. ZIPAX - EFFECT OF PARTICLE-SIZE [J].
DONE, JN ;
KNOX, JH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1972, 10 (10) :606-&
[7]  
DONE JN, 1973, GAS CHROMATOGRAPHY 1, P145
[8]   EFFECT OF INTRAPARTICLE CONVECTION ON THE CHROMATOGRAPHY OF BIOMACROMOLECULES [J].
FREY, DD ;
SCHWEINHEIM, E ;
HORVATH, C .
BIOTECHNOLOGY PROGRESS, 1993, 9 (03) :273-284
[9]   DISPERSION IN STACKED-MEMBRANE CHROMATOGRAPHY [J].
FREY, DD ;
VANDEWATER, R ;
ZHANG, BB .
JOURNAL OF CHROMATOGRAPHY, 1992, 603 (1-2) :43-47
[10]   LATERAL DIFFUSION AND LOCAL NONEQUILIBRIUM IN GAS CHROMATOGRAPHY [J].
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY, 1961, 5 (01) :61-&