Assessment of activated sludge viability with flow cytometry

被引:117
作者
Ziglio, G
Andreottola, G
Barbesti, S
Boschetti, G
Bruni, L
Foladori, P
Villa, R
机构
[1] Univ Trent, Dept Civil & Environm Engn, I-38050 Trento, Italy
[2] SOIS, Biol & Chem Labs, I-38100 Trento, Italy
关键词
activated sludge; flow cytometry; fluorescent probes; membrane integrity; enzymatic activity; OUR; kinetic constants;
D O I
10.1016/S0043-1354(01)00228-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of the study was to evaluate the applicability of fluorescent dyes and multiparameter flow cytometry for the rapid and direct viability/activity assessment of activated sludge samples taken from wastewater treatment plants. Viability and activity of the biomass were estimated respectively through cellular membrane integrity, staining with SYBR Green I and Propidium Iodide, and through fluorogenic dyes capable of detecting enzymatic activity, as FDA and BCECF-AM. A procedure has been developed to disaggregate sludge flocs before dyes staining and cytometric analysis. The developed procedure allows a high recovery of bacteria with good accuracy and repeatability, and minimize the damage of the cells suspension obtained from the disaggregation of the flocs. These measurements were applied to estimate the two main parameters required to define the biological activated sludge process: the endogenous decay rate and the specific growth rate in exponential phase with high F/M ratio. Oxygen utilization rate measurements (OUR) were conducted to conventionally monitor the activity of the biomass. The preliminary data are encouraging and support the possibility to investigate bacteria dynamics on wastewater treatment plants. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:460 / 468
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 1995, Standard methods for examination of water and waste water, V19th
[2]   A new method for the assessment of heterotrophic endogenous respiration rate under aerobic and anoxic conditions [J].
Avcioglu, E ;
Orhon, D ;
Sözen, S .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (8-9) :95-103
[3]  
Barbesti S, 2000, CYTOMETRY, V40, P214, DOI 10.1002/1097-0320(20000701)40:3<214::AID-CYTO6>3.0.CO
[4]  
2-M
[5]   THE USE OF FLUOROGENIC ESTERS TO DETECT VIABLE BACTERIA BY FLOW-CYTOMETRY [J].
DIAPER, JP ;
EDWARDS, C .
JOURNAL OF APPLIED BACTERIOLOGY, 1994, 77 (02) :221-228
[6]   CONSIDERATIONS IN THE PROCESS DESIGN OF NUTRIENT REMOVAL ACTIVATED-SLUDGE PROCESSES [J].
EKAMA, GA ;
SIEBRITZ, IP ;
MARAIS, GV .
WATER SCIENCE AND TECHNOLOGY, 1983, 15 (3-4) :283-318
[7]  
GUJER W, 1995, WATER SCI TECHNOL, V31, P1, DOI 10.1016/0273-1223(95)00175-M
[8]  
HENZE M, 1987, 1 IAWQ IAWPRC
[9]   ESTIMATION OF VIABLE BIOMASS IN WASTE-WATER AND ACTIVATED-SLUDGE BY DETERMINATION OF ATP, OXYGEN UTILIZATION RATE AND FDA HYDROLYSIS [J].
JORGENSEN, PE ;
ERIKSEN, T ;
JENSEN, BK .
WATER RESEARCH, 1992, 26 (11) :1495-1501
[10]  
KAPPELER J, 1992, WATER SCI TECHNOL, V25, P125