Lesion detection and characterization in a breast US phantom: Results of the ACRIN 6666 investigators

被引:41
作者
Berg, WA
Blume, JD
Cormack, JB
Mendelson, EB
Madsen, EL
机构
[1] Amer Coll Radiol Imaging Network, Amer Radiol Serv, Lutherville Timonium, MD 21093 USA
[2] Brown Univ, Ctr Stat Sci, Providence, RI 02912 USA
[3] Northwestern Univ, Sch Med, Dept Radiol, Chicago, IL 60611 USA
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
D O I
10.1148/radiol.2393051069
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate ultrasonographic (US) lesion detection and characterization in a breast phantom by potential investigators in a screening US protocol, American College of Radiology Imaging Network (ACRIN) 6666. Materials and Methods: National Cancer Institute Cancer Experimental Therapeutic Protocol review and ACRIN internal institutional review board approved the protocol; potential investigators were informed of the study purpose prior to participation. Six equivalent anthropomorphic phantoms were prepared with 17 masses (2 - 10 mm in mean diameter) in different locations at different depths. Sixty-six investigators, experienced in breast US, from 23 institutions scanned a phantom with high-frequency linear-array transducers (12 - 5 MHz). Lesion location, diameters, echogenicity, shape, and posterior features were recorded. Reader-specific phantom maps were generated and compared with known lesion locations and features. Results from 64 observers could be analyzed and were masked to investigator identity. Agreement on US features was measured with kappa statistics. A generalized linear model generated log relative risks for detection rates as a function of lesion diameter, depth, and features. Results: Of 17 lesions, a median of 14 (82%) were detected (range, 9 - 16), and 86% of observers detected at least 12 lesions. Of 1088 potential detections, 861 (79.1%) were made. Among 5-10-mm lesions, 499 (97.5%) of 512 detections were made (excluding a 6-mm "skin" lesion seen by only seven observers [11%]). One 4-mm mass was seen by 53 observers (83%). Among 3-mm lesions, 274 (71.4%) of 384 detections were made. One 2-mm lesion was seen by 28 (44%) observers. Relative risk of detection decreased to 0.55 (95% confidence interval: 0.51, 0.59) for each centimeter increase in lesion depth. Agreement was slight for lesion shape (kappa = 0.14), substantial for echogenicity (kappa = 0.61), and moderate for posterior features (kappa = 0.45). Feature description errors were common for 2-4-mm lesions; only 33% of 3-mm anechoic masses were so characterized. Among eight 6-10-mm lesions, investigators erred in feature description of a median of 1 lesion (mean, 1.3; range, 0 - 4). Conclusion: US detection and description of lesions in a breast phantom were highly consistent for lesions 5 - 10 mm in diameter; those smaller than 5 mm were less reliably identified or characterized by experienced investigators.
引用
收藏
页码:693 / 702
页数:10
相关论文
共 36 条
  • [1] Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer
    Berg, WA
    Gutierrez, L
    NessAiver, MS
    Carter, WB
    Bhargavan, M
    Lewis, RS
    Ioffe, OB
    [J]. RADIOLOGY, 2004, 233 (03) : 830 - 849
  • [2] Rationale for a trial of screening breast ultrasound: American College of Radiology Imaging Network (ACRIN) 6666
    Berg, WA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (05) : 1225 - 1228
  • [3] Does training in the breast imaging reporting and data system (BI-RADS) improve biopsy recommendations or feature analysis agreement with experienced breast imagers at mammography?
    Berg, WA
    D'Orsi, CJ
    Jackson, VP
    Bassett, LW
    Beam, CA
    Lewis, RS
    Crewson, PE
    [J]. RADIOLOGY, 2002, 224 (03) : 871 - 880
  • [4] BERG WA, 2004, RAD SOC N AM SCI ASS, P317
  • [5] Berg WA, 2004, WOMENS IMAGING STRAT, P95
  • [6] Interexamination variation of whole breast ultrasound
    Bosch, AM
    Kessels, AGH
    Beets, GL
    Vranken, KLCG
    Borstlap, AC
    Von Meyenfeldt, MF
    van Engelshoven, JMA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (905) : 328 - 331
  • [7] Clinically and mammographically occult breast lesions:: Detection and classification with high-resolution sonography
    Buchberger, W
    Niehoff, A
    Obrist, P
    DeKoekkoek-Doll, P
    Dünser, M
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2000, 21 (04) : 325 - 336
  • [8] Using sonography to screen women with mammographically dense breasts
    Crystal, P
    Strano, SD
    Shcharynski, S
    Koretz, MJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 177 - 182
  • [9] D'Orsi C, 2003, ILLUSTRATED BREAST I
  • [10] Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: Results of the radiologic diagnostic oncology group V study
    Fajardo, LL
    Pisano, ED
    Caudry, DJ
    Gatsonis, CA
    Berg, WA
    Connolly, J
    Schnitt, S
    Page, DL
    McNeil, BJ
    [J]. ACADEMIC RADIOLOGY, 2004, 11 (03) : 293 - 308