Spanish implantable Cardioverter-Defibrillator Registry.: First official report of the Spanish Society of Cardiology Working Group on Implantable Cardioverter-Defibrillators (2002-2004)

被引:13
作者
Peinado, R [1 ]
Arenal, A [1 ]
Arribas, F [1 ]
Torrecilla, E [1 ]
Alvarez, M [1 ]
Ormaetxe, JM [1 ]
Pérez-Castellano, N [1 ]
机构
[1] Soc Espanola Cardiol, Grp Trabajo Desfibrilador Implantable, Secc Electrofisiol & Arritmias, Madrid, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2005年 / 58卷 / 12期
关键词
defibrillator; registry; arrhythmia;
D O I
10.1016/S0300-8932(05)74074-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To report the 2002-2004 findings of the Spanish National Implantable Cardioverter-Defibrillator (ICD) Registry, established by the Spanish Society of Cardiology Working Group on Implantable Cardioverter-Defibrillators. Material and method. Data were collected prospectively after implantation using a single-page questionnaire returned to the Spanish Society of Cardiology. Participation was voluntary. Results. The registry received reports on 925, 1,046 and 1414 implants, respectively, in the years 2002, 2003 and 2004. These figures represent 63%, 59% and 67.5%, respectively, of the total number of ICDs implanted. The reported implantation rates were 22, 24 and 33 per million, respectively, and the estimated total implantation rates were 35, 41 and 49, per million, respectively. The number of device replacements increased from 20% to 30% between 2002 and 2004. The majority of patients were male, their median age was 66 years, they had severe or moderate left ventricular dysfunction, and they were in functional class I or II. The most common underlying heart disease was ischemic heart disease. The main indications for an ICD were sustained monomorphic ventricular tachycardia and aborted sudden cardiac death, though the number of prophylactic indications has increased. Most ICDs were implanted in an electrophysiology laboratory by a cardiac electrophysiologist. The implantation rates of dual-chamber ICDs and ICDs with cardiac resynchronization therapy were approximately 30% and 15%, respectively. Very few complications occurred during implantation. Conclusions. The Spanish National ICD Registry contains a representative sample of ICD implantations performed in the country. The registry is one of the largest reported.
引用
收藏
页码:1435 / 1449
页数:15
相关论文
共 27 条
[1]   Updated appraisal of pacing lead performance from the Danish Pacemaker Register: The reliability of bipolar pacing leads has improved [J].
Arnsbo, P ;
Moller, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (09) :1401-1406
[2]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[3]   Survey of cardiac pacing and implanted defibrillator practice patterns in the United States in 1997 [J].
Bernstein, AD ;
Parsonnet, V .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (05) :842-855
[4]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[5]   Guidelines of the Spanish society of cardiology on requirements and equipment in electrophysiology [J].
Brugada, J ;
Alzueta, FJ ;
Asso, A ;
Farré, J ;
Olalla, JJ ;
Tercedor, L .
REVISTA ESPANOLA DE CARDIOLOGIA, 2001, 54 (07) :887-891
[6]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[7]   Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone [J].
Connolly, SJ ;
Gent, M ;
Roberts, RS ;
Dorian, P ;
Roy, D ;
Sheldon, RS ;
Mitchell, LB ;
Green, MS ;
Klein, GJ ;
O'Brien, B .
CIRCULATION, 2000, 101 (11) :1297-1302
[8]   Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials [J].
Connolly, SJ ;
Hallstrom, AP ;
Cappato, R ;
Schron, EB ;
Kuck, KH ;
Zipes, DP ;
Greene, HL ;
Boczor, S ;
Domanski, M ;
Follmann, D ;
Gent, M ;
Roberts, RS .
EUROPEAN HEART JOURNAL, 2000, 21 (24) :2071-2078
[9]  
de los Reyes Lopez M, 1994, Rev Esp Cardiol, V47, P648
[10]   The world survey of cardiac pacing and implantable cardioverter defibrillators: Calendar year 1997 - Europe [J].
Ector, H ;
Rickards, AF ;
Kappenberger, L ;
Linde, C ;
Vardas, P ;
Oto, A ;
Santini, M ;
Sutton, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (05) :863-868