MRI diffusion tensor reconstruction with PROPELLER data acquisition

被引:50
作者
Cheryauka, AB [1 ]
Lee, JN
Samsonov, AA
Defrise, M
Gullberg, GT
机构
[1] Univ Utah, Ctr Adv Med Technol, Dept Radiol, Salt Lake City, UT 84108 USA
[2] Univ Utah, Sci Comp & Imaging Inst, Sch Comp, Salt Lake City, UT 84108 USA
[3] Free Univ Brussels, AZ VUB Univ Hosp, Div Nucl Med, Brussels, Belgium
[4] EO Lawrence Berkeley Natl Lab, Dept Nucl Med & Funct Imaging, Berkeley, CA 94720 USA
关键词
D O I
10.1016/j.mri.2003.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
MRI diffusion imaging is effective in measuring the diffusion tensor in brain, cardiac, liver, and spinal tissue. Diffusion tensor tomography MRI (DTT MRI) method is based on reconstructing the diffusion tensor field from measurements of projections of the tensor field. Projections are obtained by appropriate application of rotated diffusion gradients. In the present paper, the potential of a novel data acquisition scheme, PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction), is examined in combination with DTT MRI for its capability and sufficiency for diffusion imaging. An iterative reconstruction algorithm is used to reconstruct the diffusion tensor field from rotated diffusion weighted blades by appropriate rotated diffusion gradients. DTT MRI with PROPELLER data acquisition shows significant potential to reduce the number of weighted measurements, avoid ambiguity in reconstructing diffusion tensor parameters, increase signal-to-noise ratio, and decrease the influence of signal distortion. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 30 条
[1]
ANALYSIS OF BOUNDED VARIATION PENALTY METHODS FOR ILL-POSED PROBLEMS [J].
ACAR, R ;
VOGEL, CR .
INVERSE PROBLEMS, 1994, 10 (06) :1217-1229
[2]
HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[3]
Analysis of partial volume effects in diffusion-tensor MRI [J].
Alexander, AL ;
Hasan, KM ;
Lazar, M ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :770-780
[4]
ALEXANDER AL, 2002, P 10 M INT SOC MAGN, P436
[5]
COMPARATIVE-ANALYSIS OF THROUGH-TRANSMISSION ULTRASONIC BULK WAVE METHODS FOR PHASE-VELOCITY MEASUREMENTS IN ANISOTROPIC MATERIALS [J].
CHU, YC ;
ROKHLIN, SI .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (06) :3204-3212
[6]
Global total variation minimization [J].
Dibos, F ;
Koepfler, G .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 2000, 37 (02) :646-664
[7]
INTERPOLATION AND THE DISCRETE PAPOULIS-GERCHBERG ALGORITHM [J].
FERREIRA, PJSG .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1994, 42 (10) :2596-2606
[8]
Nonuniform fast Fourier transforms using min-max interpolation [J].
Fessler, JA ;
Sutton, BP .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (02) :560-574
[9]
PROJECTION RECONSTRUCTION TECHNIQUES FOR REDUCTION OF MOTION EFFECTS IN MRI [J].
GLOVER, GH ;
PAULY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :275-289
[10]
MOTION ARTIFACTS IN FMRI - COMPARISON OF 2DFT WITH PR AND SPIRAL SCAN METHODS [J].
GLOVER, GH ;
LEE, AT .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :624-635