Dissociation of biomolecules using a ultraviolet matrix-assisted laser desorption/ionisation time-of-flight/curved field reflectron tandem mass spectrometer equipped with a differential-pumped collision cell

被引:32
作者
Belgacem, Omar
Bowdler, Andrew
Brookhouse, Ian
Brancia, Francesco L.
Raptakis, Emmanuel
机构
[1] Wharfside, Shimadzu Biotech, Manchester M17 1GP, Lancs, England
[2] Wharfside, Shimadzu Res Lab Europe, Manchester M17 1GP, Lancs, England
关键词
D O I
10.1002/rcm.2486
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A commercial matrix-assisted laser desorption/ionisation time-of-flight (MALDI-ToF) instrument equipped with a curved field reflectron (CFR) was modified in order to perform collision-induced dissociation (CID) on a variety of biomolecules. The incorporation of a high-resolution ion gate together with a collision cell within the field-free region allowed tandem mass analysis (MS/MS), without the necessity to decelerate the precursor ions prior to activation. The simultaneous detection of all product ions remained possible by using the CFR. To test the MS/MS performances, ACTH (fragment 1-17), a complex high mannose carbohydrate (Man)(8)(GlcNac)(2) and a lysophosphatidylcholine lipid (18:1) were analysed on the modified instrument. Direct comparison with the low-energy product ion spectra, acquired on a MALDI quadrupole ion trap (QIT) two-stage reflectron time-of flight (ReToF) mass spectrometer, showed significant differences in the types of product ions observed. The additional ions detected were a clear indication of the high-energy fragmentation processes occurring in the collision cell. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1653 / 1660
页数:8
相关论文
共 20 条
[1]   Absolute values of the electron mobility in hydrogen [J].
Bradbury, NE ;
Nielsen, RA .
PHYSICAL REVIEW, 1936, 49 (05) :0388-0393
[2]  
Cheng CF, 2000, MASS SPECTROM REV, V19, P398
[3]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[4]   A CURVED FIELD REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER FOR THE SIMULTANEOUS FOCUSING OF METASTABLE PRODUCT IONS [J].
CORNISH, TJ ;
COTTER, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (09) :781-785
[5]   Tandem time-of-flight mass spectrometry with a curved field reflectron [J].
Cotter, RJ ;
Gardner, BD ;
Iltchenko, S ;
English, RD .
ANALYTICAL CHEMISTRY, 2004, 76 (07) :1976-1981
[6]   High efficiency MALDI-QIT-ToF mass spectrometer [J].
Ding, L ;
Kawatoh, E ;
Tanaka, K ;
Smith, AJ ;
Kumashiro, S .
CHARGED PARTICLE OPTICS IV, 1999, 3777 :144-155
[7]  
Harvey DJ, 1997, J MASS SPECTROM, V32, P167, DOI 10.1002/(SICI)1096-9888(199702)32:2<167::AID-JMS472>3.0.CO
[8]  
2-Q
[9]   Fragmentation of N-linked glycans with a matrix-assisted laser desorption/ionization ion trap time-of-flight mass spectrometer [J].
Harvey, DJ ;
Martin, RL ;
Jackson, KA ;
Sutton, CW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (24) :2997-3007
[10]   MATRIX-ASSISTED ULTRAVIOLET-LASER DESORPTION OF NONVOLATILE COMPOUNDS [J].
KARAS, M ;
BACHMANN, D ;
BAHR, U ;
HILLENKAMP, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 78 :53-68