asynchronous generators; diesel engines; distributed power generation; invertors; photovoltaic power systems; power capacitors; power distribution control; power distribution faults; power generation control; power generation faults; power grids; power system harmonics; power system interconnection; power system stability; power utilisation; switchgear; synchronous generators; voltage control; wind turbines; fault ride through capability; dynamic power grid support; distributed power system interconnection; medium voltage grid; FRT; utility-scale PV power plant; negative sequence control scheme; positive sequence control scheme; DC-bus double-line-frequency ripple; voltage stress reduction; grid-tied inverter power switch; DC-link capacitor; low-order voltage harmonics; current harmonics; wind turbine induction generator; diesel engine; synchronous generator; voltage dip mitigation; voltage response enhancement; stability; asymmetrical grid fault;
D O I
10.1049/iet-gtd.2013.0154
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Integration of dynamic grid support is required for distributed power systems that are interconnected with medium voltage grids. This study proposes a comprehensive control solution to enhance fault ride through (FRT) capability for utility-scale photovoltaic (PV) power plants. Based on positive and negative sequence control schemes and PV characteristics, the approach alleviates dc-bus double-line-frequency ripples, reduces voltage stress on inverter power switches and DC-link capacitors, and minimises undesirable low-order voltage and current harmonics that are presented on the ac side. The study proposes a new feature to achieve superior FRT performance by using the overload capability of grid-tied inverters. A weak electric grid is used for the test case including a wind turbine induction generator, diesel engine driven synchronous generators and various loads. A comprehensive simulation verified the capability of the proposed control schemes for mitigating the voltage dip, enhancing the voltage response and further improving the stability of interconnected distributed generation in reaction to severe unbalanced voltage conditions because of asymmetrical grid faults.
引用
收藏
页码:1027 / 1036
页数:10
相关论文
共 8 条
[1]  
[Anonymous], 2008, GUID GEN PLANTS CONN
[2]  
ENTSO-E, 2012, NETW COD REQ GRID CO
[3]  
Goodwin GC, 2001, CONTROL SYSTEM DESIGN, pXXIII
[4]  
IEEE Std, 2011, IEEE GUID DES OP INT
[5]  
Kim S. B., 2013, IEEE T APPL SUPERCON, V23
[6]   Comprehensive Approach to Modeling and Simulation of Photovoltaic Arrays [J].
Villalva, Marcelo Gradella ;
Gazoli, Jonas Rafael ;
Ruppert Filho, Ernesto .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) :1198-1208
[7]   Power Loss Comparison of Single- and Two-Stage Grid-Connected Photovoltaic Systems [J].
Wu, Tsai-Fu ;
Chang, Chih-Hao ;
Lin, Li-Chiun ;
Kuo, Chia-Ling .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (02) :707-715
[8]   Topology study of photovoltaic interface for maximum power point tracking [J].
Xiao, Weidong ;
Ozog, Nathan ;
Dunford, William G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (03) :1696-1704