Velamentous umbilical cord insertion may be suspected from maternal serum alpha-fetoprotein and hCG

被引:16
作者
Heinonen, S [1 ]
Ryynanen, M [1 ]
Kirkinen, P [1 ]
Saarikoski, S [1 ]
机构
[1] KUOPIO UNIV HOSP,DEPT OBSTET & GYNECOL,SF-70211 KUOPIO,FINLAND
来源
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY | 1996年 / 103卷 / 03期
关键词
D O I
10.1111/j.1471-0528.1996.tb09707.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Patients with unexplained elevations in second trimester maternal serum cr-fetoprotein or human chorionic gonadotrophin (hCG) concentrations are at increased risk as regards a variety of pregnancy complications and adverse perinatal outcomes. Evidence suggests that elevated cc-fetoprotein and hCG concentrations may, in some case, be sensitive indicators of underlying placental pathology, either vascular or inflammatory in nature. The present study was carried out to compare these biochemical markers in pregnancies complicated by velamentous umbilical cord insertion (VCI) with normal pregnancies. Design An observational study. Participants Maternal serum hCG and alpha-fetoprotein concentrations were measured in samples from 76 singleton pregnancies complicated by VCI and from 5200 chromosomally normal controls at 15 weeks of gestation. Results Maternal serum hCG concentrations were elevated (mean 1.47 multiples of median (MoM)) in affected pregnancies, whereas a-fetoprotein levels were lower (mean 0.88 MoM) in the subjects than in the controls. In relation to Down's syndrome risk assessment, the pattern of the two markers indicated high risk more often in VCI than in pregnancies with normal umbilical insertion. Accordingly, the increased false positive rate (26.3% compared with 6.6%) resulted in a higher rate of invasive techniques for fetal karyotyping in these pregnancies. Conclusions In obstetric practice, elevated maternal serum hCG concentrations may in some cases be explained as being solely the result of abnormal insertion, which provides a link between unexplained hCG elevation and adverse pregnancy outcome. We suggest colour flow Doppler imaging of cord insertion in pregnancies followed because of unexplained hCG elevation or a false positive result in Down's syndrome screening.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 16 条
[1]   MARGINAL INSERTION OF THE CORD AND PREMATURE LABOR [J].
BRODY, S ;
FRENKEL, DA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1953, 65 (06) :1305-1312
[2]   CORD SERUM ALPHA-FETOPROTEIN AND DOWNS-SYNDROME [J].
CUCKLE, HS ;
WALD, NJ ;
LINDENBAUM, RH .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1986, 93 (04) :408-410
[3]  
CUCKLE HS, 1987, BRIT J OBSTET GYNAEC, V99, P495
[4]   CLINICAL-SIGNIFICANCE AND SONOGRAPHIC DIAGNOSIS OF VELAMENTOUS UMBILICAL-CORD INSERTION [J].
EDDLEMAN, KA ;
LOCKWOOD, CJ ;
BERKOWITZ, GS ;
LAPINSKI, RH ;
BERKOWITZ, RL .
AMERICAN JOURNAL OF PERINATOLOGY, 1992, 9 (02) :123-126
[6]   ELEVATED 2ND TRIMESTER MATERNAL SERUM BETA-HCG CONCENTRATIONS AND SUBSEQUENT ADVERSE PREGNANCY OUTCOME [J].
GRAVETT, CP ;
BUCKMASTER, JG ;
WATSON, PT ;
GRAVETT, MG .
AMERICAN JOURNAL OF MEDICAL GENETICS, 1992, 44 (04) :485-486
[7]  
KOUYOUMDJIAN A, 1980, OBSTET GYNECOL, V56, P737
[8]  
KRONE HA, 1965, Z GEBURTSH PERINATOL, V165, P205
[9]  
MACRI JN, 1978, LANCET, V1, P660
[10]   RELATIONSHIP BETWEEN PLACENTAL SHAPE, CORD INSERTION, LOBES AND GESTATIONAL OUTCOME [J].
NORDENVALL, M ;
SANDSTEDT, B ;
ULMSTEN, U .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1988, 67 (07) :611-616