Hilar and mediastinal invasion of bronchogenic carcinoma: Evaluation by thin-section electron-beam computed tomography

被引:10
作者
Takahashi, M
Shimoyama, K
Murata, K
Mori, M
Nitta, N
Mishina, A
Matsuo, H
Morita, R
Fujino, S
Inoue, S
Kato, H
机构
[1] Department of Radiology, Shiga University of Medical Sciences, Seta-Tsukinowa, Otsu
[2] Second Department of Surgery, Shiga University of Medical Sciences, Seta-Tsukinowa, Otsu
关键词
bronchogenic carcinoma; direct invasion; electron-beam computed tomography; incremental dynamic computed tomography;
D O I
10.1097/00005382-199707000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of thin-section incremental dynamic computed tomography (IDCT) using an electron-beam scanner in evaluating hilar or mediastinal invasion of bronchogenic carcinoma was assessed. Thirty-seven patients with proven bronchogenic carcinoma, contiguous with hilar or mediastinal structures, underwent IDCT. The area of contact was scanned using 19 contiguous 3-mm thick sections during injection of contrast material. The degree of contact between mass and pulmonary artery or vein and their distortion were recorded. Irregular thickening of the bronchial wall, soft tissue within the lumen, or distortion were used to determine airway involvement. Sixty-nine sites were assessed retrospectively and compared with pathology reports. The accuracy, sensitivity, and specificity in evaluating invasion of the pulmonary artery were 75.0%, 77.8%, and 71.4%, respectively. Limited reliability also was found for invasion of the main bronchus and ''secondary'' carina, with accuracies of 66.7% and 70.5%, sensitivities of 75.0% and 70.0%, and specificities of 57.1% and 71.4%, respectively. Thin-section IDCT with electron beam scanner is not accurate in the detection of hilar or mediastinal invasion by bronchogenic carcinoma.
引用
收藏
页码:195 / 199
页数:5
相关论文
共 14 条
[1]   COMPUTED-TOMOGRAPHY IN THE PREOPERATIVE EVALUATION OF BRONCHOGENIC-CARCINOMA [J].
BARON, RL ;
LEVITT, RG ;
SAGEL, SS ;
WHITE, MJ ;
ROPER, CL ;
MARBARGER, JP .
RADIOLOGY, 1982, 145 (03) :727-732
[2]   CT EVALUATION OF BLUNT ABDOMINAL-TRAUMA IN CHILDREN - COMPARISON OF ULTRAFAST AND CONVENTIONAL CT [J].
BRODY, AS ;
SEIDEL, FG ;
KUHN, JP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) :803-806
[3]   INDETERMINATE MEDIASTINAL INVASION IN BRONCHOGENIC-CARCINOMA - CT EVALUATION [J].
GLAZER, HS ;
KAISER, LR ;
ANDERSON, DJ ;
MOLINA, PL ;
EMAMI, B ;
ROPER, CL ;
SAGEL, SS .
RADIOLOGY, 1989, 173 (01) :37-42
[4]   MEDIASTINAL INVASION BY BRONCHOGENIC-CARCINOMA - CT SIGNS [J].
HERMAN, SJ ;
WINTON, TL ;
WEISBROD, GL ;
TOWERS, MJ ;
MENTZER, SJ .
RADIOLOGY, 1994, 190 (03) :841-846
[5]   PEDIATRIC PULMONARY-DISEASE - ASSESSMENT WITH HIGH-RESOLUTION ULTRAFAST CT [J].
LYNCH, DA ;
BRASCH, RC ;
HARDY, KA ;
WEBB, WR .
RADIOLOGY, 1990, 176 (01) :243-248
[6]  
MARTINI N, 1985, J THORAC CARDIOV SUR, V90, P639
[7]   Peribronchovascular interstitium of the pulmonary hilum: Normal and abnovmal findings on thin-section electron-beam CT [J].
Murata, K ;
Takahashi, M ;
Mori, M ;
Shimoyama, K ;
Nitta, N ;
Mishina, A ;
Matsuo, H ;
Morita, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :309-312
[8]   CHEST-WALL AND MEDIASTINAL INVASION BY LUNG-CANCER - EVALUATION WITH MULTISECTION EXPIRATORY DYNAMIC CT [J].
MURATA, K ;
TAKAHASHI, M ;
MORI, M ;
SHIMOYAMA, K ;
MISHINA, A ;
FUJINO, S ;
ITOH, H ;
MORITA, R .
RADIOLOGY, 1994, 191 (01) :251-255
[9]   CENTRAL LUNG MASSES - PREDICTION WITH CT OF NEED FOR PNEUMONECTOMY VERSUS LOBECTOMY [J].
QUINT, LE ;
GLAZER, GM ;
ORRINGER, MB .
RADIOLOGY, 1987, 165 (03) :735-738
[10]   PREOPERATIVE STAGING OF NON-SMALL-CELL CARCINOMA OF THE LUNG - IMAGING METHODS [J].
QUINT, LE ;
FRANCIS, IR ;
WAHL, RL ;
GROSS, BH ;
GLAZER, GM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (06) :1349-1359