Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study

被引:54
作者
Benic, Goran I. [1 ]
Gallucci, German O. [2 ]
Mokti, Muizzaddin [2 ]
Haemmerle, Christoph H. F. [1 ]
Weber, Hans-Peter [3 ]
Jung, Ronald E. [1 ]
机构
[1] Univ Zurich, Ctr Dent Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, CH-8032 Zurich, Switzerland
[2] Harvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA 02111 USA
关键词
crown; dental implants; diameter; fixed partial denture; humans; narrow; radiographic; randomized controlled trial; survival; titanium; titanium-zirconium; MECHANICAL-PROPERTIES; SURVIVAL RATE; TOOTH; RESTORATIONS; SITES;
D O I
10.1111/jcpe.12156
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
AimTo test whether titanium-zirconium (TiZr) 3.3mm diameter implants perform differently from titanium (Ti) 4.1mm diameter implants with respect to marginal bone level (MBL) and clinical parameters. Material and MethodsForty subjects in need of a single implant-supported crown in the anterior or premolar regions were recruited in two centres. After random allocation, either a Ti or a TiZr implant was placed. Definitive crowns were inserted 6months after implant placement. Implant survival, change in MBL, clinical parameters and occurrence of adverse events were assessed at the 1-year examination. ResultsAt 1year, 38 of the 40 included patients were examined (18 Ti and 20 TiZr implants). All the implants were in place and stable. From the implant placement to the 1-year examination, the change of MBL amounted to -0.40mm in the Ti group and -0.41mm in the TiZr group. There were no significant differences between the groups regarding the change in MBL, the clinical parameters and the occurrence of adverse events. ConclusionsThe use of TiZr implants with narrow diameter for the support of single crowns in the anterior and premolar regions leads to successful tissue integration and clinical performance over a 1-year period.
引用
收藏
页码:1052 / 1061
页数:10
相关论文
共 29 条
[1]
AINAMO J, 1975, INT DENT J, V25, P229
[2]
A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles - Results from a 1-Year Observation Period [J].
Al-Nawas, Bilal ;
Bragger, Urs ;
Meijer, Henny J. A. ;
Naert, Ignace ;
Persson, Rigmor ;
Perucchi, Alessandro ;
Quirynen, Marc ;
Raghoebar, Gerry M. ;
Reichert, Torsten E. ;
Romeo, Eugenio ;
Santing, Hendrik J. ;
Schimmel, Martin ;
Storelli, Stefano ;
ten Bruggenkate, Christiaan ;
Vandekerckhove, Betty ;
Wagner, Wilfried ;
Wismeijer, Daniel ;
Mueller, Frauke .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :896-904
[3]
[Anonymous], CLIN IMPLANT DENT R
[4]
A pilot study to evaluate the success and survival rate of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up [J].
Barter, Stephen ;
Stone, Paul ;
Braegger, Urs .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) :873-881
[5]
Clinical and radiographic comparison of implants in regenerated or native bone: 5-year results [J].
Benic, Goran I. ;
Jung, Ronald E. ;
Siegenthaler, David W. ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) :507-513
[6]
Stability of Contour Augmentation and Esthetic Outcomes of Implant-Supported Single Crowns in the Esthetic Zone: 3-Year Results of a Prospective Study With Early Implant Placement Postextraction [J].
Buser, Daniel ;
Wittneben, Julia ;
Bornstein, Michael M. ;
Gruetter, Linda ;
Chappuis, Vivianne ;
Belser, Urs C. .
JOURNAL OF PERIODONTOLOGY, 2011, 82 (03) :342-349
[7]
Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid®) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients [J].
Chiapasco, M. ;
Casentini, P. ;
Zaniboni, M. ;
Corsi, E. ;
Anello, T. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) :1136-1141
[8]
A 5-year prospective study on small diameter screw-shaped oral implants [J].
Comfort, MB ;
Chu, FCS ;
Chai, J ;
Wat, PYP ;
Chow, TW .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) :341-345
[9]
Davarpanah M, 2000, J Esthet Dent, V12, P186, DOI 10.1111/j.1708-8240.2000.tb00221.x
[10]
Degidi M, 2008, J PERIODONTOL, V79, P49, DOI [10.1902/jop.2008.070248, 10.1902/jop.2008.070248 ]