Ultrasensitive Multianalyte Electrochemical Immunoassay Based on Metal Ion Functionalized Titanium Phosphate Nanospheres

被引:136
作者
Feng, Li-Na [1 ]
Bian, Zhi-Ping [2 ]
Peng, Juan [1 ]
Jiang, Fang [1 ]
Yang, Guo-Hai [1 ]
Zhu, Ying-Di [1 ]
Yang, Di [2 ]
Jiang, Li-Ping [1 ]
Zhu, Jun-Jie [1 ]
机构
[1] Nanjing Univ, State Key Lab Analyt Chem Life Sci, Sch Chem & Chem Engn, Nanjing 210093, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Inst Cardiovasc Dis, Affiliated Hosp 1, Nanjing 210029, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CARDIAC TROPONIN-I; ACUTE MYOCARDIAL-INFARCTION; ACID-BINDING PROTEIN; QUARTZ-CRYSTAL MICROBALANCE; SURFACE-PLASMON RESONANCE; GOLD NANOPARTICLES; CARBON NANOTUBES; IMMUNOSENSOR; GRAPHENE; AMPLIFICATION;
D O I
10.1021/ac301438v
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A novel multianalyte electrochemical immunoassay was developed for ultrasensitive detection of human cardiopathy biomarkers cardiac troponin I (cTnI) and human heart-type fatty-acid-binding protein (FABP) using metal ion functionalized titanium phosphate nanospheres (TiP-metal ion) as labels. The metal ions could be detected directly through square wave voltammetry (SWV) without metal preconcentration, and the distinct voltammetric peaks had a close relationship with each sandwich-type immunoreaction. The position and size of the peaks reflected the identity and level of the corresponding antigen. The large amount of metal ions loading on the TiP nanospheres greatly amplified the detection signals, and the good biocompatibility of graphene nanoribbons (GONRs) retained good stability for the sandwich-type immunoassay. The proposed immunoassay exhibited high sensitivity and selectivity for the detection of cTnI and FABP. The linear relationships between electrochemical signals and the concentrations of cTnI and FABP were obtained in the range of 0.05 pg/mL-50 ng/mL and 0.05 pg/mL-50 ng/mL, respectively. The detection limits of cTnI and HIgG were 1 and 3 fg/mL (S/N = 3), respectively. Moreover, the immunoassay accurately detected the concentrations of cTnI and FABP in human serum samples, which were demonstrated to have excellent correlations with the standard enzyme linked immunosorbent assay (ELISA) method. The results suggested that the electrochemical immunoassay would be promising in the point-of-care diagnostics application of clinical screening of acute myocardial infarction (AMI) biomarkers.
引用
收藏
页码:7810 / 7815
页数:6
相关论文
共 43 条
[1]
Do we need additional markers of myocyte necrosis: the potential value of heart fatty-acid-binding protein [J].
Alhadi, HA ;
Fox, KAA .
QJM-AN INTERNATIONAL JOURNAL OF MEDICINE, 2004, 97 (04) :187-198
[2]
Gold nanoparticles mediated label-free capacitance detection of cardiac troponin I [J].
Bhalla, Vijayender ;
Carrara, Sandro ;
Sharma, Priyanka ;
Nangia, Yogesh ;
Suri, C. Raman .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :761-768
[3]
BODOR GS, 1995, CLIN CHEM, V41, P1710
[4]
Rapid analysis of fatty acid-binding proteins with immunosensors and immunotests for early monitoring of tissue injury [J].
Chan, CPY ;
Wan, TSM ;
Watkins, KL ;
Pelsers, MMAL ;
Van der Voort, DL ;
Tang, FPW ;
Lam, KHK ;
Mill, J ;
Yuan, Y ;
Lehmann, M ;
Hempel, A ;
Sanderson, JE ;
Glatz, JFC ;
Renneberg, R .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2566-2580
[5]
Biofunctional Titania Nanotubes for Visible-Light-Activated Photoelectrochemical Biosensing [J].
Chen, Da ;
Zhang, Hao ;
Li, Xiang ;
Li, Jinghong .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2253-2261
[6]
Gold nanoparticle-colloidal carbon nanosphere hybrid material: Preparation, characterization, and application for an amplified electrochemical immunoassay [J].
Cui, Rongjing ;
Liu, Chang ;
Shen, Jianming ;
Gao, Di ;
Zhu, Jun-Jie ;
Chen, Hong-Yuan .
ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (15) :2197-2204
[7]
Potential of a simplified measurement scheme and device structure for a low cost label-free point-of-care capacitive biosensor [J].
de Vasconcelos, Elder A. ;
Peres, Newton G. ;
Pereira, Cintya O. ;
da Silva, Valdinete L. ;
da Silva, Eronides F., Jr. ;
Dutra, Rosa F. .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) :870-876
[8]
Sensitive Immunosensor for Cancer Biomarker Based on Dual Signal Amplification Strategy of Graphene Sheets and Multienzyme Functionalized Carbon Nanospheres [J].
Du, Dan ;
Zou, Zhexiang ;
Shin, Yongsoon ;
Wang, Jun ;
Wu, Hong ;
Engelhard, Mark H. ;
Liu, Jun ;
Aksay, Ilhan A. ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2010, 82 (07) :2989-2995
[9]
Surface plasmon resonance immunosensor for human cardiac troponin T based on self-assembled monolayer [J].
Dutra, Rosa Fireman ;
Mendes, Renata Kelly ;
da Silva, Valdinete Lins ;
Kubota, Lauro Tatsuo .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1744-1750
[10]
Synthesis of Cd2+-functionalized titanium phosphate nanoparticles and application as labels for electrochemical immunoassays [J].
Feng, Li-Na ;
Peng, Juan ;
Zhu, Ying-Di ;
Jiang, Li-Ping ;
Zhu, Jun-Jie .
CHEMICAL COMMUNICATIONS, 2012, 48 (37) :4474-4476