Patterns of stiffness during clinical examination of the glenohumeral joint

被引:22
作者
McQuade, KJ
Selley, I
Cvitkovic, J
机构
[1] Vet Adm Med Ctr, Sch Med, Dept Physiotherapy, Baltimore, MD 21201 USA
[2] New York Med Coll, Valhalla, NY 10595 USA
[3] Mercy Coll, Dobbs Ferry, NY 10522 USA
关键词
shoulder joint; biomechanics; mobilization; glenohumeral; stiffness; shoulder examination; joint laxity;
D O I
10.1016/S0268-0033(99)00024-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Objective. The purpose of our study was to develop a quantitative technique for performing clinical laxity tests, and to characterize the force-displacement response patterns in normal shoulders during two commonly applied clinical tests in different arm positions. Design. The study was an in vivo clinical experiment, Background. We developed a method to objectively quantify the effects of clinical laxity testing at the shoulder. No previous studies have measured the applied force during clinical testing along with the displacement so that glenohumeral joint stiffness could be determined in vivo. Methods. Manually applied forces were measured and shoulder displacement was recorded using electromagnetic tracking sensors during clinical stability testing in 21 subjects with normal shoulders. End-range stiffness was calculated and compared across all test conditions using repeated measures analysis of variance. Results. The maximum force applied by the examiner to reach clinical end-point across all tests ranged from 101-113 N The stiffest position for posterior drawer test was at 180 degrees C of abduction with the arm in internal rotation. This position was the most compliant position for the anterior drawer test. Only by internally rotating the arm did the force-dislpacement pattern change significantly (P< 0.05). For anterior drawer tests, the patterns changed significantly (P < 0.05) only when the arm was in external rotation. Conclusions. Results showed that end-range stiffness was predominantly dependent on humeral rotation angle and not effected by arm abduction angle for the three angles studied. Stiffness from anterior drawer tests was highest with the arm in external rotation, and stiffness from posterior drawer tests was highest with the arm in internal rotation.
引用
收藏
页码:620 / 627
页数:8
相关论文
共 27 条
[1]
APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]
3-DIMENSIONAL KINEMATICS OF GLENOHUMERAL ELEVATION [J].
AN, KN ;
BROWNE, AO ;
KORINEK, S ;
TANAKA, S ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (01) :143-149
[3]
[Anonymous], MANAGEMENT COMMON MU
[4]
TENSILE PROPERTIES OF THE INFERIOR GLENOHUMERAL LIGAMENT [J].
BIGLIANI, LU ;
POLLOCK, RG ;
SOSLOWSKY, LJ ;
FLATOW, EL ;
PAWLUK, RJ ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :187-197
[5]
CYRIAX J, TXB ORTHOPAEDIC MED, V1, P975
[6]
KINEMATIC AND FORCE DATA-COLLECTION IN BIOMECHANICS BY MEANS OF SONIC EMITTERS .1. KINEMATIC DATA-COLLECTION METHODOLOGY [J].
ENGIN, AE ;
PEINDL, RD ;
BERME, N ;
KALEPS, I .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03) :204-211
[7]
CLINICAL-ASSESSMENT OF INSTABILITY OF THE SHOULDER - WITH SPECIAL REFERENCE TO ANTERIOR AND POSTERIOR DRAWER TESTS [J].
GERBER, C ;
GANZ, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (04) :551-556
[8]
GORDON J, 1991, PRINCIPLES NEURAL SC, P565
[9]
GOULD JA, 1990, ORTHOPAEDIC SPORTS P
[10]
THE ROLE OF THE ROTATOR INTERVAL CAPSULE IN PASSIVE MOTION AND STABILITY OF THE SHOULDER [J].
HARRYMAN, DT ;
SIDLES, JA ;
HARRIS, SL ;
MATSEN, FA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (01) :53-66