Improved direct torque control of an induction generator used in a wind conversion system connected to the grid

被引:54
作者
Abdelli, Radia [1 ]
Rekioua, Djamila [1 ]
Rekioua, Toufik [1 ]
Tounzi, Abdelmounaim [2 ]
机构
[1] Bejaia Univ, Lab Technol Ind & Informat, Bejaia 06000, Algeria
[2] L2EP, Lab Elctrotech & Power Elect Lille, Lille, France
关键词
Induction generator (IG); Modulated hysteresis direct torque control (MHDTC); Direct torque control (DTC); Field oriented control method (FOC); Wind conversion system; Modulated hysteresis controller; POWER-CONTROL; TURBINE; DRIVEN; PERFORMANCE; SIMULATION;
D O I
10.1016/j.isatra.2013.03.001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a modulated hysteresis direct torque control (MHDTC) applied to an induction generator (IG) used in wind energy conversion systems (WECs) connected to the electrical grid through a back-to-back converter. The principle of this strategy consists in superposing to the torque reference a triangular signal, as in the PWM strategy, with the desired switching frequency. This new modulated reference is compared to the estimated torque by using a hysteresis controller as in the classical direct torque control (DTC). The aim of this new approach is to lead to a constant frequency and low THD in grid current with a unit power factor and a minimum voltage variation despite the wind variation. To highlight the effectiveness of the proposed method, a comparison was made with classical DTC and field oriented control method (FOC). The obtained simulation results, with a variable wind profile, show an adequate dynamic of the conversion system using the proposed method compared to the classical approaches. (c) 2013 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:525 / 538
页数:14
相关论文
共 34 条
[1]   Performances improvements and torque ripple minimization for VSI fed induction machine with direct control torque [J].
Abdelli, R. ;
Rekioua, D. ;
Rekioua, T. .
ISA TRANSACTIONS, 2011, 50 (02) :213-219
[2]   Adaptive neuro-fuzzy control of an induction motor [J].
Areed, Fayez G. ;
Haikal, Amira Y. ;
Mohammed, Reham H. .
AIN SHAMS ENGINEERING JOURNAL, 2010, 1 (01) :71-78
[3]   A modified direct torque control with fault tolerance [J].
Arnanz, Roberto ;
Miguel, Luis J. ;
Peran, Jose R. ;
Mendoza, Antonio .
CONTROL ENGINEERING PRACTICE, 2011, 19 (09) :1056-1065
[4]  
Bekka H, 2012, IREC C SOUSS TUN, P1
[5]   Current Control of the Isolated Self-Excited Induction Generator using Shunt Active Filter [J].
Bouzid, A. M. ;
Benghanem, M. ;
Hamane, B. ;
Belabbes, A. ;
Bouhamida, M. ;
Draou, A. .
TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 :349-358
[6]   The Improvement of DTC System Performance on Fuzzy Control [J].
Gao, Yuan ;
Wang, Jinkuan ;
Qiu, Xinyun .
2011 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND INFORMATION APPLICATION TECHNOLOGY ESIAT 2011, VOL 10, PT A, 2011, 10 :589-594
[7]   From linear to nonlinear control means: A practical progression [J].
Gao, ZQ .
ISA TRANSACTIONS, 2002, 41 (02) :177-189
[8]   VSC-based direct torque and reactive power control of doubly fed induction generator [J].
Hu, Jiabing ;
Yuan, Xiaoming .
RENEWABLE ENERGY, 2012, 40 (01) :13-23
[9]   Vector control of autonomous induction generator taking saturation effect into account [J].
Ididarene, K. ;
Rekioua, D. ;
Rekioua, T. ;
Tounzi, A. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) :2609-2617
[10]   Performance of an Isolated Induction Generator Under Unbalanced Loads [J].
Idjdarene, Kassa ;
Rekioua, Djamila ;
Rekioua, Toufik ;
Tounzi, Abdelmounaim .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (02) :303-311