Wave reflection quantification based on pressure waveforms alone-Methods, comparison, and clinical covariates

被引:92
作者
Hametner, Bernhard [1 ,2 ]
Wassertheurer, Siegfried [1 ,2 ]
Kropf, Johannes [1 ]
Mayer, Christopher [1 ]
Holzinger, Andreas [3 ]
Eber, Bernd [4 ]
Weber, Thomas [4 ]
机构
[1] AIT Austrian Inst Technol, Hlth & Environm Dept, Vienna, Austria
[2] Vienna Univ Technol, Dept Anal & Sci Comp, A-1040 Vienna, Austria
[3] Med Univ Graz, Inst Med Informat, Graz, Austria
[4] Klinikum Wels Grieskirchen, Dept Cardiol, Wels, Austria
关键词
Wave separation analysis; Arterial stiffness; Reflection magnitude; Augmentation pressure; Augmentation index; ARTERIAL STIFFNESS; INPUT IMPEDANCE; PULSE PRESSURE; MORTALITY; VELOCITY; RISK; FLOW;
D O I
10.1016/j.cmpb.2012.10.005
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
Within the last decade the quantification of pulse wave reflections mainly focused on measures of central aortic systolic pressure and its augmentation through reflections based on pulse wave analysis (PWA). A complementary approach is the wave separation analysis (WSA), which quantifies the total amount of arterial wave reflection considering both aortic pulse and flow waves. The aim of this work is the introduction and comparison of aortic blood flow models for WSA assessment. To evaluate the performance of the proposed modeling approaches (Windkessel, triangular and averaged flow), comparisons against Doppler measurements are made for 148 patients with preserved ejection fraction. Stepwise regression analysis between WSA and PWA parameters are performed to provide determinants of methodological differences. Against Doppler measurement mean difference and standard deviation of the amplitudes of the decomposed forward and backward pressure waves are comparable for Windkessel and averaged flow models. Stepwise regression analysis shows similar determinants between Doppler and Windkessel model only. The results indicate that the Windkessel method provides accurate estimates of wave reflection in subjects with preserved ejection fraction. The comparison with waveforms derived from Doppler ultrasound as well as recently proposed simple triangular and averaged flow waves showed that this approach may reduce variability and provide realistic results. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:250 / 259
页数:10
相关论文
共 36 条
[1]
Central blood pressure measurements and antihypertensive therapy a consensus document [J].
Agabiti-Rosei, Enrico ;
Mancia, Giuseppe ;
O'Rourke, Michael F. ;
Roman, Mary J. ;
Safar, Michel E. ;
Smulyan, Harold ;
Wang, Ji-Guang ;
Wilkinson, Ian B. ;
Williams, Bryan ;
Vlachopoulos, Charalambos .
HYPERTENSION, 2007, 50 (01) :154-160
[2]
Reflecting on posture [J].
Avolio, Alberto ;
Parati, Gianfranco .
JOURNAL OF HYPERTENSION, 2011, 29 (04) :655-657
[3]
Role of Pulse Pressure Amplification in Arterial Hypertension Experts' Opinion and Review of the Data [J].
Avolio, Alberto P. ;
Van Bortel, Luc M. ;
Boutouyrie, Pierre ;
Cockcroft, John R. ;
McEniery, Carmel M. ;
Protogerou, Athanase D. ;
Roman, Mary J. ;
Safar, Michel E. ;
Segers, Patrick ;
Smulyan, Harold .
HYPERTENSION, 2009, 54 (02) :375-383
[4]
Chen CH, 1997, CIRCULATION, V95, P1827
[5]
Active standing reduces wave reflection in the presence of increased peripheral resistance in young and old healthy individuals [J].
Davis, Shyrin C. A. T. ;
Westerhof, Berend E. ;
van den Bogaard, Bas ;
Bogert, Lysander W. J. ;
Truijen, Jasper ;
Kim, Yu-Sok ;
Westerhof, Nico ;
van Lieshout, Johannes J. .
JOURNAL OF HYPERTENSION, 2011, 29 (04) :682-689
[6]
ON THE MINIMUM WORK CRITERION IN OPTIMAL-CONTROL MODELS OF LEFT-VENTRICULAR EJECTION [J].
HAMALAINEN, RP ;
HAMALAINEN, JJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (11) :951-956
[7]
Pulsatile but not steady component of blood pressure predicts cardiovascular events in coronary patients [J].
Jankowski, Piotr ;
Kawecka-Jaszcz, Kalina ;
Czarnecka, Danuta ;
Brzozowska-Kiszka, Malgorzata ;
Styczkiewicz, Katarzyna ;
Loster, Magdalena ;
Kloch-Badelek, Malgorzata ;
Wilinski, Jerzy ;
Curylo, Adam M. ;
Dudek, Dariusz .
HYPERTENSION, 2008, 51 (04) :848-855
[8]
NONINVASIVE DETERMINATION OF AGE-RELATED-CHANGES IN THE HUMAN ARTERIAL PULSE [J].
KELLY, R ;
HAYWARD, C ;
AVOLIO, A ;
OROURKE, M .
CIRCULATION, 1989, 80 (06) :1652-1659
[9]
Evaluation of Noninvasive Methods to Assess Wave Reflection and Pulse Transit Time From the Pressure Waveform Alone [J].
Kips, Jan G. ;
Rietzschel, Ernst R. ;
De Buyzere, Marc L. ;
Westerhof, Berend E. ;
Gillebert, Thierry C. ;
Van Bortel, Luc M. ;
Segers, Patrick .
HYPERTENSION, 2009, 53 (02) :142-U77
[10]
Arterial wave reflections and survival in end-stage renal failure [J].
London, GM ;
Blacher, J ;
Pannier, B ;
Guérin, AP ;
Marchais, SJ ;
Safar, ME .
HYPERTENSION, 2001, 38 (03) :434-438