Left atrial volumes assessed by three- and two-dimensional echocardiography compared to MRI estimates

被引:192
作者
Rodevand, O
Bjornerheim, R
Ljosland, M
Maehle, J
Smith, HJ
Ihlen, H
机构
[1] Univ Oslo, Rikshosp, Natl Hosp, Dept Cardiol, N-0027 Oslo, Norway
[2] Univ Oslo, Rikshosp, Natl Hosp, Dept Radiol, N-0027 Oslo, Norway
[3] Norwegian Univ Sci & Technol, Dept Physiol & Biomed Engn, N-7034 Trondheim, Norway
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1999年 / 15卷 / 05期
关键词
echocardiography; heart atrium; left atrial volume; magnetic resonance imaging; three-dimensional echocardiography;
D O I
10.1023/A:1006276513186
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of the present study was to establish the accuracy and reproducibility of left atrial volume measurements by three-dimensional (3D) echocardiography compared to 2D biplane and monoplane measurements. Background: No echocardiographic technique is generally accepted as optimal for estimation of left atrial size. Methods: Left atrial volumes of 18 unselected cardiac patients were obtained with magnetic resonance imaging (MRI) (volumes 145 +/- 58 ml). These volumes were compared with those obtained with different echocardiographic methods: a multiplane 3D method based on 90 images acquired by apical probe rotation, a simplified 3D method using only the three standard apical views, and 2D biplane and monoplane methods based on area-length, disc summation and spherical formulas. Results: The echocardiographic methods significantly underestimated maximum left atrial volumes as obtained by MRI by 14-37% (p < 0.001). Accuracy, expressed as 1 SD of individual estimates around this systematic underestimation, was 25 to 27% for all methods, except for the 2D 2-chamber monoplane method (37%). Interobserver coefficient of variation was between 14 and 20% for all methods (n.s.). Conclusion: All echocardiographic methods significantly underestimated left atrial volumes as obtained by MRI. A minor non-significant improvement in individual echocardiographic estimates by the 3D methods was obtained at the cost of more time consumption. In unselected patients ultrasound image quality precludes significant improvement of left atrial volume measurements by the applied 3D methods.
引用
收藏
页码:397 / 410
页数:14
相关论文
共 41 条
  • [1] Aakhus S, 1994, J Am Soc Echocardiogr, V7, P571
  • [2] Altman DG, 1990, PRACTICAL STAT MED R
  • [3] ANDERSON DC, 1992, ANN INTERN MED, V116, P6
  • [4] LEFT ATRIAL SIZE AND THE RISK OF STROKE AND DEATH - THE FRAMINGHAM HEART-STUDY
    BENJAMIN, EJ
    DAGOSTINO, RB
    BELANGER, AJ
    WOLF, PA
    LEVY, D
    [J]. CIRCULATION, 1995, 92 (04) : 835 - 841
  • [5] BIGGER TJJ, 1998, EPIDEMIOLOGICAL MECH, P943
  • [6] Measurement error
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 312 (7047) : 1654 - 1654
  • [7] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [8] Statistics notes: Measurement error proportional to the mean .23.
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 313 (7049) : 106 - 106
  • [9] USEFULNESS OF LEFT ATRIAL AND LEFT-VENTRICULAR CHAMBER SIZES AS PREDICTORS OF THE SEVERITY OF MITRAL REGURGITATION
    BURWASH, IG
    BLACKMORE, GL
    KOILPILLAI, CJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (07) : 774 - 779
  • [10] FEIGENBAUM H, 1994, ECHOCARDIOGR-J CARD, V3, P166