Electrocatalytic oxidation of oxalic acid on palladium nanoparticles encapsulated on polyamidoamine dendrimer-grafted multi-walled carbon nanotubes hybrid material

被引:36
作者
Ahmar, Hamid [1 ]
Fakhari, Ali Reza [1 ]
Nabid, Mohammad Reza [1 ]
Rezaei, Seyed Jamal Tabatabaei [1 ]
Bide, Yasamin [1 ]
机构
[1] Shahid Beheshti Univ, Fac Sci, Dept Chem, Tehran, Iran
关键词
Pd nanoparticles; Polyamidoamine dendrimer; Multi-walled carbon nanotubes; Electrochemical sensor; Modified electrode; CHEMICALLY-MODIFIED ELECTRODES; ASCORBIC-ACID; ELECTROCHEMICAL DETERMINATION; GLUCOSE; ELECTROANALYSIS; VOLTAMMETRY; CHEMISTRY; CATALYSIS; FILMS;
D O I
10.1016/j.snb.2012.05.041
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
In this work, a heterogeneous catalyst based on palladium nanoparticles encapsulated on polyamidoamine dendrimer-grafted multi-walled carbon nanotubes (PdNPs/PAMAM-MWCNTs) hybrid material was used as an electrode modifier. The catalyst was dissolved in N,N-Dimethylformamide (DMF) and immobilized on the surface of glassy carbon electrode using drop casting method to fabricate PdNPs/PAMAM-MWCNTs modified electrode. The modified electrode showed good catalytic activity for the electrooxidation of oxalic acid in 0.1 M HClO4 with a substantial decrease in anodic overpotentials (450 mV) and increase in anodic peak current (about 3 times) in comparison with unmodified electrode. The values of electron transfer coefficients (alpha = 0.37) and diffusion coefficient (D = 2.12 x 10(-6) cm(2) s(-1)) were calculated for oxalic acid using electrochemical approaches. The cyclic voltammetry showed a linear response in the range of 0.03-5.0 mM with detection limit (3 sigma) of 0.02 mM for oxalic acid. The experimental results also showed that the sensor has good reproducibility (R.S.D = 4.3% for 5.0 mM, n = 5), long-term stability (over than 100 analysis with intermittent use), and a fast response time (5 s). Finally, the modified electrode was successfully applied to determine the oxalic acid content in spinach. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 39 条
[1]
Role of carbon nanotubes in electroanalytical chemistry -: A review [J].
Agui, Lourdes ;
Yanez-Sedeno, Paloma ;
Pingarron, Jose M. .
ANALYTICA CHIMICA ACTA, 2008, 622 (1-2) :11-47
[2]
Electrocatalytic reduction of dioxygen at a modified glassy carbon electrode based on Nafion®-dispersed single-walled carbon nanotubes and cobalt-porphyrin with palladium nanoparticles in acidic media [J].
Ahmed, Mohammad Shamsuddin ;
Jeong, Haesang ;
You, Jung-Min ;
Jeon, Seungwon .
ELECTROCHIMICA ACTA, 2011, 56 (13) :4924-4929
[3]
Alkire C. Richard, 2009, ADV ELECTROCHEMICAL
[4]
[Anonymous], 2001, ELECTROCHEMICAL METH
[5]
Electrochemical sensors [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3285-3298
[6]
Dendrimer-Encapsulated Bimetallic Nanoparticles: Synthesis, Characterization, and Applications to Homogeneous and Heterogeneous Catalysis [J].
Chandler, Bert D. ;
Gilbertson, John D. .
DENDRIMER CATALYSIS, 2006, 20 :97-120
[7]
Platinum Catalysts Prepared with Functional Carbon Nanotube Defects and Its Improved Catalytic Performance for Methanol Oxidation [J].
Chen, JH ;
Wang, MY ;
Liu, B ;
Fan, Z ;
Cui, KZ ;
Kuang, Y .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (24) :11775-11779
[8]
Nonenzymatic amperometric sensing of glucose by using palladium nanoparticles supported on functional carbon nanotubes [J].
Chen, Xiao-mei ;
Lin, Zhi-jie ;
Chen, De-Jun ;
Jia, Tian-tian ;
Cai, Zhi-min ;
Wang, Xiao-ru ;
Chen, Xi ;
Chen, Guo-nan ;
Oyama, Munetaka .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (07) :1803-1808
[9]
ELECTROANALYSIS WITH ELECTRODES MODIFIED BY INORGANIC FILMS [J].
COX, JA ;
JAWORSKI, RK ;
KULESZA, PJ .
ELECTROANALYSIS, 1991, 3 (09) :869-877
[10]
Dendrimer-encapsulated metal nanoparticles: Synthesis, characterization, and applications to catalysis [J].
Crooks, RM ;
Zhao, MQ ;
Sun, L ;
Chechik, V ;
Yeung, LK .
ACCOUNTS OF CHEMICAL RESEARCH, 2001, 34 (03) :181-190