Transesophageal echocardiography for quantifying size of patent foramen ovale in patients with cryptogenic cerebrovascular events

被引:82
作者
Schuchlenz, HW
Weihs, W
Beitzke, A
Stein, JI
Gamillscheg, A
Rehak, P
机构
[1] LKH Univ Klinikum Graz, Med Abt 2, Dept Med 2, A-8036 Graz, Austria
[2] LKH Univ Klinikum Graz, Dept Pediat, A-8036 Graz, Austria
[3] LKH Univ Klinikum Graz, Dept Surg, Div Med Engn & Comp, A-8036 Graz, Austria
关键词
cerebral ischemia; contrast media; echocardiography; transesophageal; embolism; paradoxical; foramen ovale; patent;
D O I
10.1161/hs0102.100883
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Patent foramen ovale (PFO) is a risk factor for paradoxical embolism, and severe shunting and wide opening of PFO are risk factors for severe and recurrent cerebrovascular events. Neither contrast echocardiography nor 2-dimensional (2D) measurement of PFO size have been validated or compared with invasive balloon sizing. Methods-We performed transesophageal echocardiography (TEE) in 100 patients with cryptogenic stroke and catheter closure of PFO. The amount of contrast shunting through the PFO during cubital and femoral contrast delivery and the PFO size measured by 2D TEE were compared with balloon sizing. Results-There was a significant correlation (r(2)=0.8; P<0.0001) between 2D TEE measurement and invasive balloon sizing. Mean balloon-sized PFO diameter was significantly larger than mean PFO diameter measured by 2D TEE (8.3 +/- 2.6 versus 5.2 +/- 1.7 mm). Semiquantitative contrast TEE correlated with PFO size (r(2)=0.7; P<0.0001) only if the contrast agent was administered through a femoral vein. Correlation was poor when the contrast agent was administered via a cubital vein. Conclusions-We conclude that 2D TEE measurement of a PFO size is more accurate than the traditionally used contrast technique.
引用
收藏
页码:293 / 296
页数:4
相关论文
共 27 条
  • [1] How should patients with patent foramen ovale be managed?
    Alp, N
    Clarke, N
    Banning, A
    [J]. HEART, 2001, 85 (03) : 242 - 244
  • [2] TRANSCATHETER CLOSURE OF PATENT FORAMEN OVALE AFTER PRESUMED PARADOXICAL EMBOLISM
    BRIDGES, ND
    HELLENBRAND, W
    LATSON, L
    FILIANO, J
    NEWBURGER, JW
    LOCK, JE
    [J]. CIRCULATION, 1992, 86 (06) : 1902 - 1908
  • [3] Should percutaneous devices be used to close a patent foramen ovale after cerebral infarction or TIA?
    Chambers, J
    [J]. HEART, 1999, 82 (05) : 537 - 538
  • [4] Cheitlin MD, 1997, CIRCULATION, V95, P1686
  • [5] Cheng T O, 2000, Circulation, V101, pE226
  • [6] TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS
    CHIMOWITZ, MI
    NEMEC, JJ
    MARWICK, TH
    LORIG, RJ
    FURLAN, AJ
    SALCEDO, EE
    [J]. NEUROLOGY, 1991, 41 (12) : 1902 - 1904
  • [7] De Castro S, 1995, J Am Soc Echocardiogr, V8, P217
  • [8] Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts - Comparison of different procedures and different contrast agents
    Droste, DW
    Kriete, JU
    Stypmann, J
    Castrucci, M
    Wichter, T
    Tietje, R
    Weltermann, B
    Young, P
    Ringelstein, EB
    [J]. STROKE, 1999, 30 (09) : 1827 - 1832
  • [9] Superiority of the combination of blood and agitated saline for routine contrast enhancement
    Fan, S
    Nagai, T
    Luo, H
    Atar, S
    Naqvi, T
    Birnbaum, Y
    Lee, S
    Siegel, RJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (02) : 94 - 98
  • [10] FEINSTEIN SB, 1984, J AM COLL CARDIOL, V4, P595, DOI 10.1016/S0735-1097(84)80107-2