Clipless laparoscopic cholecystectomy by ultrasonic dissection

被引:67
作者
Bessa, Samer S. [1 ]
Al-Fayoumi, Tarek A. [1 ]
Katri, Khaled M. [1 ]
Awad, Ahmed T. [1 ]
机构
[1] Univ Alexandria, Dept Gen Surg, Fac Med, Alexandria 44118, Egypt
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | 2008年 / 18卷 / 04期
关键词
D O I
10.1089/lap.2007.0227
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Ultrasonically activated devices have been used in gallbladder dissection in the laparoscopic cholecystectomy with encouraging results. The aim of this study was to compare between the safety and efficacy of the harmonic shears and the commonly used clip and cautery technique in achieving safe closure and division of the cystic duct in the laparoscopic cholecystectomy. Methods: In this prospective study, 120 patients with symptomatic gallstone disease were randomly assigned to either the harmonic scalpel laparoscopic cholecystectomy group (HS group = 60 patients) where closure and division of the cystic duct was achieved solely by the harmonic shears or the clip and cautery laparoscopic cholecystectomy group (C&C group = 60 patients). Results: Neither minor nor major bile leaks were encountered in either group. Similarly, no bile-duct injuries were encountered in the present study. The incidence of gallbladder perforation was statistically significantly higher in the C&C group, compared to the HS group (30 vs. 10%, respectively; P = 0.002). The median operative time was statistically significantly shorter in the HS group than in the C&C group (32 vs. 40 minutes, respectively; P = 0.000). No statistically significant difference was found in the incidence of postoperative complications between both groups. Conclusions: The harmonic shears are as safe and effective as the commonly used clip and cautery technique in achieving safe closure and division of the cystic duct in the laparoscopic cholecystectomy. Further, it provides a superior alternative to the currently used high-frequency monopolar technology in terms of shorter operative time and lower incidence of gallbladder perforation.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 33 条
[1]
Experimental comparison of the ultrasonically-activated scalpel to electrosurgery and laser surgery for laparoscopic use [J].
Amaral, JF ;
Chrostek, CA .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (04) :324-331
[2]
AMARAL JF, 1994, SURG LAPAROSC ENDOSC, V4, P92
[3]
Geissler B, 1998, ZBL CHIR, V123, P102
[4]
The dramatic reality of biliary tract injury during laparoscopic cholecystectomy - An anonymous multicenter Belgian survey of 65 patients [J].
Gigot, JF ;
Etienne, J ;
Aerts, R ;
Wibin, E ;
Dallemagne, B ;
Deweer, F ;
Fortunati, D ;
Legrand, M ;
Vereecken, L ;
Doumont, JM ;
VanReepinghen, P ;
Beguin, C .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (12) :1171-1178
[5]
REDUCED POSTOPERATIVE HOSPITALIZATION AFTER LAPAROSCOPIC CHOLECYSTECTOMY [J].
GRACE, PA ;
QUERESHI, A ;
COLEMAN, J ;
KEANE, R ;
MCENTEE, G ;
BROE, P ;
OSBORNE, H ;
BOUCHIERHAYES, D .
BRITISH JOURNAL OF SURGERY, 1991, 78 (02) :160-162
[6]
Bile leakage resulting from clip displacement of the cystic duct stump - A potential pitfall of laparoscopic cholecystectomy [J].
Hanazaki, K ;
Igarashi, J ;
Sodeyama, H ;
Matsuda, Y .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (02) :168-171
[7]
Laparoscopic cholecystectomy by ultrasonic dissection without cystic duct and artery ligature [J].
Hüscher, CGS ;
Lirici, MM ;
Di Paola, M ;
Crafa, F ;
Napolitano, C ;
Mereu, A ;
Recher, A ;
Corradi, A ;
Amini, M .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (03) :442-451
[8]
Hüscher CGS, 1999, SURG ENDOSC-ULTRAS, V13, P1256
[9]
Randomized clinical trial of ultrasonic versus electrocautery dissection of the gallbladder in laparoscopic cholecystectomy [J].
Janssen, IMC ;
Swank, DJ ;
Boonstra, O ;
Knipscheer, BC ;
Klinkenbijl, JHG ;
van Goor, H .
BRITISH JOURNAL OF SURGERY, 2003, 90 (07) :799-803
[10]
Recurrent abdominal abscess secondary to a dropped laparoscopic clip: CT imaging [J].
Labuski, MR ;
Wise, SW .
ABDOMINAL IMAGING, 1999, 24 (02) :191-192