Liquid exclusion-adsorption chromatography, a new technique for isocratic separation of nonionic surfactants - IV. Two-dimensional separation of fatty alcohol ethoxylates with focusing of fractions

被引:37
作者
Trathnigg, B [1 ]
Rappel, C [1 ]
机构
[1] Graz Univ, Inst Chem, A-8010 Graz, Austria
关键词
liquid exclusion-adsorption chromatography liquid chromatography under critical conditions fatty alcohol ethoxylates; ethoxylates; alcohol ethoxylates; surfactants;
D O I
10.1016/S0021-9673(02)00076-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fatty alcohol ethoxylates can be analyzed using a combination of liquid chromatography under critical conditions as the first dimension and liquid exclusion-adsorption chromatography as the second dimension. Transfer of fractions from the first to the second dimension is achieved using the full adsorption-desorption (FAD) technique. The peaks of interest in the first dimension are trapped on a short precolumn before injecting them into the second dimension. Full adsorption is achieved by increasing the water content in the mobile phase before the FAD column. When the fractions are desorbed by switching to the mobile phase of the second dimension, they are focused and reconcentrated. In this way, a full resolution of oligomers is achieved. As both dimensions are run in isocratic mode, density and refractive index detection can be applied, which allows an accurate quantitation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 163
页数:15
相关论文
共 28 条
[1]   Molecular characterization of block copolymers by means of liquid chromatography I. Potential and limitations of full adsorption-desorption procedure in separation of block copolymers [J].
Berek, D ;
Nguyen, SH ;
Hild, G .
EUROPEAN POLYMER JOURNAL, 2000, 36 (06) :1101-1111
[2]  
Berek D, 2000, J APPL POLYM SCI, V75, P857
[3]   CHROMATOGRAPHIC INVESTIGATIONS OF MACROMOLECULES IN THE CRITICAL RANGE OF LIQUID-CHROMATOGRAPHY .1. FUNCTIONALITY TYPE AND COMPOSITION DISTRIBUTION IN POLYETHYLENE OXIDE AND POLYPROPYLENE OXIDE COPOLYMERS [J].
GORSHKOV, AV ;
MUCH, H ;
BECKER, H ;
PASCH, H ;
EVREINOV, VV ;
ENTELIS, SG .
JOURNAL OF CHROMATOGRAPHY, 1990, 523 :91-102
[4]   COMPARISON OF THE EVAPORATIVE LIGHT-SCATTERING DETECTOR (ELSD) AND REFRACTIVE-INDEX DETECTOR (RID) IN LIPID ANALYSIS [J].
HOPIA, AI ;
OLLILAINEN, VM .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (12) :2469-2482
[5]  
HUNKELER D, 1993, ACS SYM SER, V521, P90
[6]   LIQUID-CHROMATOGRAPHY OF POLYMER MIXTURES APPLYING A COMBINATION OF EXCLUSION AND FULL ADSORPTION MECHANISMS .2. ELUENT SWITCHING APPROACH [J].
JANCO, M ;
BEREK, D ;
PRUDSKOVA, T .
POLYMER, 1995, 36 (17) :3295-3299
[7]  
JANCO M, 1995, J APPL POLYM SCI, V55, P393
[8]   DETERMINATION OF FUNCTIONALITY AND MOLAR-MASS DISTRIBUTION OF ALIPHATIC POLYESTERS BY ORTHOGONAL LIQUID-CHROMATOGRAPHY .1. OFF-LINE INVESTIGATION OF POLY(1,6-HEXANEDIOL ADIPATES) [J].
KRUGER, RP ;
MUCH, H ;
SCHULZ, G .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (14-15) :3069-3090
[9]   OPTIMIZATIONS OF HPLC CONDITIONS TO ANALYZE WIDELY DISTRIBUTED ETHOXYLATED ALKYLPHENOL SURFACTANTS [J].
MARQUEZ, N ;
ANTON, RE ;
USUBILLAGA, A ;
SALAGER, JL .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (05) :1147-1169
[10]   Operational characteristics of the evaporative light scattering detector used in analysis of ethoxylated alcohols [J].
Miszkiewicz, W ;
Szymanowski, J .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (07) :1013-1032