Can mechanical myotonometry or electromyography be used for the prediction of intramuscular pressure?

被引:55
作者
Korhonen, RK
Vain, A
Vanninen, E
Viir, R
Jurvelin, JS
机构
[1] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
[2] Univ Calgary, Fac Kinesiol, Human Performance Lab, Calgary, AB T2N 1N4, Canada
[3] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, Kuopio 70211, Finland
[4] Univ Tartu, Inst Expt Phys & Technol, EE-51010 Tartu, Estonia
[5] Rheumatism Fdn Hosp, SF-18120 Heinola, Finland
关键词
intramuscular pressure; biomechanics; myotonometry; electromyography; isometric contraction;
D O I
10.1088/0967-3334/26/6/006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of the study was to characterize the electromechanical properties of skeletal muscle during isometric loading as well as to assess the potential of estimating intramuscular pressure by electrical and mechanical methods. Simultaneous electromyography (EMG), mechanical myotonometry (MYO, frequency and decrement of decay) and intramuscular pressure (IMP) measurements were conducted at rest and during short-term and long-term isometric contractions in patients with chronic pain in the anterior leg or dorsal forearm. The EMG amplitude and MyO(freq) accounted significantly (24-73%, p < 0.0001) for the variations in the IMP under short-term isometric loading. The IMP, EMG and MyO(freq) increased linearly with the relative muscle load (r = 0.868-0.993, p < 0.05). Mean values of EMG amplitudes at the contraction levels of 75% and 100% maximum voluntary contraction (MVC) and MYOfreq values at all contraction levels (0-100% MVC) were higher for subjects with pathological values of IMP than for those with IMP values in the normal range. Total changes in IMP and EMG amplitude during 1 min isometric contraction were linearly interrelated (r = 0.747, p < 0.0001). We conclude that both surface electromyography and myotonometry parameters are indicative of intramuscular pressure, but neither of these methods can be used alone to diagnose non-invasively chronic compartment syndrome with acceptable accuracy.
引用
收藏
页码:951 / 963
页数:13
相关论文
共 31 条
[1]   INTRAMUSCULAR PRESSURE AND ELECTROMYOGRAPHY AS INDEXES OF FORCE DURING ISOKINETIC EXERCISE [J].
ARATOW, M ;
BALLARD, RE ;
CRENSHAW, AG ;
STYF, J ;
WATENPAUGH, DE ;
KAHAN, NJ ;
HARGENS, AR .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (06) :2634-2640
[2]   THE EFFECTS OF SELECTIVE MATRIX DEGRADATION ON THE SHORT-TERM COMPRESSIVE PROPERTIES OF ADULT HUMAN ARTICULAR-CARTILAGE [J].
BADER, DL ;
KEMPSON, GE ;
EGAN, J ;
GILBEY, W ;
BARRETT, AJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1992, 1116 (02) :147-154
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
BOIKO M, 1997, THESIS U TARTU TARTU
[5]  
BOURNE RB, 1989, CLIN ORTHOP RELAT R, V240, P97
[6]   PH-INDUCED EFFECTS ON MEDIAN FREQUENCY AND CONDUCTION-VELOCITY OF THE MYOELECTRIC SIGNAL [J].
BRODY, LR ;
POLLOCK, MT ;
ROY, SH ;
DE LUCA, CJ ;
CELLI, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (05) :1878-1885
[7]   Differential responses in intramuscular pressure and EMG fatigue indicators during low-vs. high-level isometric contractions to fatigue [J].
Crenshaw, AG ;
Karlsson, S ;
Gerdle, B ;
Friden, J .
ACTA PHYSIOLOGICA SCANDINAVICA, 1997, 160 (04) :353-361
[8]  
FUNG YC, 1993, BIOMECHANCIS MECH PR
[9]   INTRAMUSCULAR PRESSURE AND ELECTROMYOGRAPHY IN 4 SHOULDER MUSCLES [J].
JARVHOLM, U ;
PALMERUD, G ;
KARLSSON, D ;
HERBERTS, P ;
KADEFORS, R .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (04) :609-619
[10]   INTRAMUSCULAR PRESSURE AND MUSCLE BLOOD-FLOW IN SUPRASPINATUS [J].
JARVHOLM, U ;
STYF, J ;
SUURKULA, M ;
HERBERTS, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1988, 58 (03) :219-224