SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)

被引:506
作者
Achenbach, Stephan [1 ]
Delgado, Victoria [2 ]
Hausleiter, Joerg [3 ]
Schoenhagen, Paul [4 ,5 ]
Min, James K. [6 ]
Leipsic, Jonathon A. [7 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Leiden Univ, Dept Cardiol, Med Ctr, Leiden, Netherlands
[3] Univ Munich, Klinikum Grosshadern, Dept Cardiol, D-8000 Munich, Germany
[4] Cleveland Clin Fdn, Imaging Inst, Cleveland, OH 44195 USA
[5] Cleveland Clin Fdn, Inst Heart & Vasc, Cleveland, OH 44195 USA
[6] David Geffen UCLA Sch Med, Cedars Sinai Heart Inst, Los Angeles, CA USA
[7] St Pauls Hosp, Dept Radiol, Vancouver, BC V6Z 1Y6, Canada
关键词
Transcatheter aortic valve replacement; TAVR; Transcatheter aortic valve implantation; TAVI; Guidelines; Compute tomography; CONTRAST INJECTION; REGURGITATION; STENOSIS; ROOT; PROSTHESIS; DEPLOYMENT; OUTCOMES; ECHOCARDIOGRAPHY; DEFINITIONS; DIMENSIONS;
D O I
10.1016/j.jcct.2012.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relatively large sheaths necessary to introduce the prosthesis. CT imaging also provides accurate dimensions of the ascending aorta, aortic root, and aortic annulus which are of importance for prosthesis sizing, and initial data indicate that compared with echocardiographic sizing, CT-based sizing of the prosthesis may lead to better results for postprocedural aortic valve regurgitation. Finally, CT permits one to predict appropriate fluoroscopic projections which are oriented orthogonal to the aortic valve plane. This consensus document provides recommendations about the use of CT imaging in patients scheduled for TAVR/TAVI, including data acquisition, interpretation, and reporting. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:366 / 380
页数:15
相关论文
共 53 条
[1]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[2]   Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation [J].
Altiok, Ertunc ;
Koos, Ralf ;
Schroeder, Joerg ;
Brehmer, Kathrin ;
Hamada, Sandra ;
Becker, Michael ;
Mahnken, Andreas H. ;
Almalla, Mohammad ;
Dohmen, Guido ;
Autschbach, Ruediger ;
Marx, Nikolaus ;
Hoffmann, Rainer .
HEART, 2011, 97 (19) :1578-1584
[3]  
Arnold M, 2013, J CARDIOVASC COMPUT, V7, pxxx
[4]   Prediction of Optimal Deployment Projection for Transcatheter Aortic Valve Replacement Angiographic 3-Dimensional Reconstruction of the Aortic Root Versus Multidetector Computed Tomography [J].
Binder, Ronald K. ;
Leipsic, Jonathon ;
Wood, David ;
Moore, Teri ;
Toggweiler, Stefan ;
Willson, Alex ;
Gurvitch, Ronen ;
Freeman, Melanie ;
Webb, John G. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) :247-252
[5]   Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root [J].
Blanke, Philipp ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Siepe, Matthias ;
Pache, Gregor ;
Euringer, Wulf ;
Geibel-Zehender, Annette ;
Bode, Christopher ;
Langer, Mathias ;
Beyersdorf, Friedhelm ;
Zehender, Manfred .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) :540-548
[6]   Direct Aortic Access for Transcatheter Self-Expanding Aortic Bioprosthetic Valves Implantation [J].
Bruschi, Giuseppe ;
de Marco, Federico ;
Botta, Luca ;
Cannata, Aldo ;
Oreglia, Jacopo ;
Colombo, Paola ;
Barosi, Alberto ;
Colombo, Tiziano ;
Nonini, Sandra ;
Paino, Roberto ;
Klugmann, Silvio ;
Martinelli, Luigi .
ANNALS OF THORACIC SURGERY, 2012, 94 (02) :497-503
[7]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[8]   Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123
[9]   Incidence and Management of CoreValve Dislocation During Transcatheter Aortic Valve Implantation [J].
Geisbuesch, Sarah ;
Bleiziffer, Sabine ;
Mazzitelli, Domenico ;
Ruge, Hendrik ;
Bauernschmitt, Robert ;
Lange, Ruediger .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (06) :531-536
[10]   Clinical Outcomes After Transcatheter Aortic Valve Replacement Using Valve Academic Research Consortium Definitions A Weighted Meta-Analysis of 3,519 Patients From 16 Studies [J].
Genereux, Philippe ;
Head, Stuart J. ;
Van Mieghem, Nicolas M. ;
Kodali, Susheel ;
Kirtane, Ajay J. ;
Xu, Ke ;
Smith, Craig ;
Serruys, Patrick W. ;
Kappetein, A. Pieter ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (25) :2317-2326