In vivo reproducibility of a new non-invasive diagnostic tool for three-dimensional knee evaluation

被引:20
作者
Hagemeister, N
Yahia, LH
Duval, N
de Guise, JA
机构
[1] CHUM, Ctr Rech, Ctr Rech Musculosquelett Arthrose, Lab Rech Imagerie & Orthopedie, Montreal, PQ H2L 4M1, Canada
[2] Ecole Polytech, Biomech Biomat Res Grp, Montreal, PQ H3C 3A7, Canada
[3] Ecole Technol Super, Lab Imagerie Vis & Intelligence Artificielle, Montreal, PQ, Canada
关键词
knee ligaments; diagnostic tool; 3D kinematics; 3D knee analyser;
D O I
10.1016/S0968-0160(99)00004-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Essential steps in the development of a new diagnostic tool are the evaluation of its precision, its reproducibility and its reliability. In this paper, the experimental protocol for the evaluation of three-dimensional (3D) knee kinematics using a new 3D knee analyser developed for the pre- and post-operative evaluation of the ligament injured knee is presented. The results of an in vivo reproducibility study of the system on 16 healthy subjects are also exposed. For all subjects, an adjusted coefficient of multiple correlation R-a was calculated for 10 movements. We showed that for most subjects abduction/adduction and internal/external tibial rotation movement during 10 knee flexions was very reproducible. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 20 条
[1]
[Anonymous], 1996, KNEE, DOI DOI 10.1016/0968-0160(96)00210-4
[2]
ARTHROMETRIC EVALUATION OF KNEES THAT HAVE A TORN ANTERIOR CRUCIATE LIGAMENT [J].
BACH, BR ;
WARREN, RF ;
FLYNN, WM ;
KROLL, M ;
WICKIEWIECZ, TL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (09) :1299-1306
[3]
ELMAACH I, 1997, P INT S ADV BIOM ISA
[4]
IS THE KT1000 KNEE LIGAMENT ARTHROMETER RELIABLE [J].
FORSTER, IW ;
WARRENSMITH, CD ;
TEW, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (05) :843-847
[5]
GARGOURI I, 1997, THESIS ECOLE POLYTEC
[6]
A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[7]
HAMEL G, 1997, P INT PCL STUD GROUP
[8]
HAMEL G, 1997, THESIS ECOLE POLYTEC
[9]
HAMEL G, 1997, P INT S ADV BIOM ISA
[10]
Intratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee [J].
Huber, FE ;
Irrgang, JJ ;
Harner, C ;
Lephart, S .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (04) :479-485