In vitro hemocompatibility testing of UV-modified hyaluronan hydrogels

被引:100
作者
Amarnath, LP
Srinivas, A
Ramamurthi, A [1 ]
机构
[1] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
[2] Med Univ S Carolina, Dept Cell Biol & Anat, Charleston, SC 29425 USA
基金
美国国家科学基金会;
关键词
hylan; ultraviolet; blood-material interactions; thrombosis;
D O I
10.1016/j.biomaterials.2005.08.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hydrogels (hylans) based on cross-linked hyaluronan (HA) are potentially good biomaterials for vascular tissue engineering applications because they are highly non-antigenic and -immunogenic. To facilitate surface endothelialization, vital to vascular deployment, we irradiated the gel surface with low wavelength UV light. This process micro-textures the smooth gel surface to provide sites for cell anchorage and causes limited scission of native long-chain HA yielding smaller fragments that elicit an enhanced cell response. In the current in vitro study, we assessed the effects of UV irradiation on the short-term (< 45 min) interaction between hylan gels and human blood cells (RBCs, platelets) and coagulation proteins at physiologic temperature. Although the lowered hydrophilicity of irradiated (UV) hylans elicited greater vascular cell response relative to unmodified (U) hylans, platelet deposition was unaffected and much lower compared to collagen-coated glass controls. The adhered platelets were rounded or mildly pseudopodic and did not express p-selectin, an activation marker. Both gel types induced identical, and minimal platelet release as measured using an platelet factor 4 ELISA, and identically deferred the intrinsic and extrinsic coagulation pathways. Both gel types induced elevated levels of contact activation of bound, but not plasma-phase factor XII relative to controls. Hemolysis rates were also identical and within accepted standards. We conclude that UV-treatment of hylans, useful to improve surface endothelialization, does not compromise their short-term hemocompatibility, vital to their use as vascular implant materials. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1416 / 1424
页数:9
相关论文
共 33 条
[1]   Surface modification of chitosan membranes by complexation-interpenetration of anionic polysaccharides for improved blood compatibility in hemodialysis [J].
Amiji, MM .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1996, 8 (04) :281-298
[2]   MATRIX ENGINEERING [J].
BALAZS, EA ;
BLAND, PA ;
DENLINGER, JL ;
GOLDMAN, AI ;
LARSEN, NE ;
LESHCHINER, EA ;
LESHCHINER, A ;
MORALES, B .
BLOOD COAGULATION & FIBRINOLYSIS, 1991, 2 (01) :173-178
[3]   SURFACE-MEDIATED DEFENSE REACTIONS - THE PLASMA CONTACT ACTIVATION SYSTEM [J].
COLMAN, RW .
JOURNAL OF CLINICAL INVESTIGATION, 1984, 73 (05) :1249-1253
[4]   THE COAGULATION CASCADE - INITIATION, MAINTENANCE, AND REGULATION [J].
DAVIE, EW ;
FUJIKAWA, K ;
KISIEL, W .
BIOCHEMISTRY, 1991, 30 (43) :10363-10370
[5]   Stent placement to prevent restenosis after angioplasty in small coronary arteries [J].
Doucet, S ;
Schalij, MJ ;
Vrolix, MCM ;
Hilton, D ;
Chenu, P ;
de Bruyne, B ;
Udayachalerm, W ;
Seth, A ;
Bilodeau, L ;
Reiber, JHC ;
Harel, F ;
Lespérance, J .
CIRCULATION, 2001, 104 (17) :2029-2033
[6]   INFLUENCE OF CORONARY VESSEL SIZE ON RENARROWING PROCESS AND LATE ANGIOGRAPHIC OUTCOME AFTER SUCCESSFUL BALLOON ANGIOPLASTY [J].
FOLEY, DP ;
MELKERT, R ;
SERRUYS, PW .
CIRCULATION, 1994, 90 (03) :1239-1251
[7]  
FRISCHI J, THROMB HAEMOSTASIS, V10, P264
[8]   POLYURETHANE SURFACE MODIFICATION BY GRAFT-POLYMERIZATION OF ACRYLAMIDE FOR REDUCED PROTEIN ADSORPTION AND PLATELET-ADHESION [J].
FUJIMOTO, K ;
TADOKORO, H ;
UEDA, Y ;
IKADA, Y .
BIOMATERIALS, 1993, 14 (06) :442-448
[9]  
Goodman SL, 1999, J BIOMED MATER RES, V45, P240, DOI 10.1002/(SICI)1097-4636(19990605)45:3<240::AID-JBM12>3.0.CO
[10]  
2-C