Surface cupricated SnO2-ZnO thick films as a H2S gas sensor

被引:148
作者
Wagh, MS
Patil, LA [1 ]
Seth, T
Amalnerkar, DP
机构
[1] Pratap Coll, Mat Sci Lab, Amalner 425401, India
[2] Ctr Mat Elect Technol, Govt India, Pune 8, Maharashtra, India
关键词
cupricated; SnO2-ZnO-CuO; H2S gas sensor;
D O I
10.1016/S0254-0584(03)00232-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
SnO2 (95 wt.%)-ZnO(5 wt.%) thick films have been prepared by screen printing and firing process. Sensitivity of these films to H2S gas was examined. These films are found better sensitive to H2S gas than pure SnO2 films. It may be due to porosity created by ZnO into SnO2 matrix. SnO2-ZnO film operates at 250degreesC while pure SnO2 at 350degreesC to have a maximum sensitivity. SnO2-ZnO thick films were surface cupricated to give extremely high sensitivity, fast response and recovery to H2S gas. In cuprication process, SnO2-ZnO films were dipped into aqueous solution of cupric chloride for different intervals of time and then sintered.
引用
收藏
页码:228 / 233
页数:6
相关论文
共 22 条
[1]   Structural characterization of nanocrystalline SnO2 by X-ray and Raman spectroscopy [J].
Abello, L ;
Bochu, B ;
Gaskov, A ;
Koudryavtseva, S ;
Lucazeau, G ;
Roumyantseva, M .
JOURNAL OF SOLID STATE CHEMISTRY, 1998, 135 (01) :78-85
[2]   Surface-ruthenated tin oxide as a novel hydrocarbon sensor [J].
Chaudhary, VA ;
Mulla, IS ;
Sainkar, SR ;
Belhekar, AA ;
Vijayamohanan, K .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 65 (2-3) :197-202
[3]   Selective hydrogen sensing properties of surface functionalized tin oxide [J].
Chaudhary, VA ;
Mulla, IS ;
Vijayamohanan, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (2-3) :154-160
[4]   SnO2:Bi2O3 based CO sensor:: Laser-Raman, temperature programmed desorption and X-ray photoelectron spectroscopic studies [J].
Devi, GS ;
Manorama, SV ;
Rao, VJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :98-105
[5]   RAMAN-SPECTRA OF SINGLE-CRYSTAL CUO [J].
HAGEMANN, H ;
BILL, H ;
SADOWSKI, W ;
WALKER, E ;
FRANCOIS, M .
SOLID STATE COMMUNICATIONS, 1990, 73 (06) :447-451
[6]  
HAUPTMANN P, 1991, SENSORS PRINCIPLES A, P115
[7]   APPLICATION OF MIXED-OXIDE CAPACITOR TO THE SELECTIVE CARBON-DIOXIDE SENSOR .1. MEASUREMENT OF CARBON-DIOXIDE SENSING CHARACTERISTICS [J].
ISHIHARA, T ;
KOMETANI, K ;
HASHIDA, M ;
TAKITA, Y .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (01) :173-176
[8]   Heating power-controlled micro-gas sensor array [J].
Lim, JW ;
Kang, DW ;
Lee, DS ;
Huh, JS ;
Lee, DD .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :139-144
[9]   IN-SITU CHARACTERIZATION OF CU-ZSM-5 BY X-RAY-ABSORPTION SPECTROSCOPY - XANES STUDY OF THE COPPER OXIDATION-STATE DURING SELECTIVE CATALYTIC REDUCTION OF NITRIC-OXIDE BY HYDROCARBONS [J].
LIU, DJ ;
ROBOTA, HJ .
APPLIED CATALYSIS B-ENVIRONMENTAL, 1994, 4 (2-3) :155-165
[10]   IMPROVEMENT OF COPPER OXIDE-TIN OXIDE SENSOR FOR DILUTE HYDROGEN-SULFIDE [J].
MAEKAWA, T ;
TAMAKI, J ;
MIURA, N ;
YAMAZOE, N .
JOURNAL OF MATERIALS CHEMISTRY, 1994, 4 (08) :1259-1262