By the spleen, we calculated a time-delay correction of the input function for quantitation of hepatic blood flow with oxygen-15 water and dynamic positron emission tomography. The time delay (Delta t) between the sample site and the spleen was calculated based on nonlinear multiple regression analysis when splenic blood flow was determined. Then hepatic blood flow was quantified by a method using the input function and incorporating Delta t, which was assumed to be equal to the time delay between the sample site and the liver. Then hepatic arterial and portal blood flows were estimated separately as well as the delay time for passage within the organs of the portal circulation. The mean coefficient of variation and the mean sum of squares of errors decreased to about 70% when total hepatic blood flow was calculated from the results for regions of interest in three slices of the same liver segment. We concluded that using the spleen for time-delay correction of the input function for measuring hepatic blood flow by this method gave satisfactory results.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 15 条
[1]  
FLEMING JS, 1983, J NUCL MED, V24, P1108
[2]   DETERMINATION OF SPLENIC BLOOD-FLOW BY INHALATION OF RADIOACTIVE RARE-GASES [J].
HUCHZERMEYER, H ;
SCHMITZFEUERHAKE, I ;
REBLIN, T .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1977, 7 (05) :345-349
[3]   ERROR ANALYSIS OF A QUANTITATIVE CEREBRAL BLOOD-FLOW MEASUREMENT USING (H2O)-O-15 AUTORADIOGRAPHY AND POSITRON EMISSION TOMOGRAPHY, WITH RESPECT TO THE DISPERSION OF THE INPUT FUNCTION [J].
IIDA, H ;
KANNO, I ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05) :536-545
[4]   EVALUATION OF REGIONAL DIFFERENCES OF TRACER APPEARANCE TIME IN CEREBRAL TISSUES USING [O-15]WATER AND DYNAMIC POSITRON EMISSION TOMOGRAPHY [J].
IIDA, H ;
HIGANO, S ;
TOMURA, N ;
SHISHIDO, F ;
KANNO, I ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
SASAKI, H ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (02) :285-288
[5]   SPLENIC BLOOD-FLOW MEASUREMENTS BY DOPPLER ULTRASOUND - A PRELIMINARY-REPORT [J].
MANOHARAN, A ;
GILL, RW ;
GRIFFITHS, KA .
CARDIOVASCULAR RESEARCH, 1987, 21 (10) :779-782
[6]  
MEYER E, 1989, J NUCL MED, V30, P1069
[7]   USE OF INDIUM-111-LABELED PLATELETS TO MEASURE SPLEEN FUNCTION [J].
PETERS, AM ;
KLONIZAKIS, I ;
LAVENDER, JP ;
LEWIS, SM .
BRITISH JOURNAL OF HAEMATOLOGY, 1980, 46 (04) :587-593
[8]   MEASUREMENT OF HEPATIC BLOOD-FLOW BY USE OF PER-RECTAL PORTAL SCINTIGRAPHY WITH XE-133 [J].
SHIOMI, S ;
KUROKI, T ;
UEDA, T ;
IKEOKA, N ;
KOBAYASHI, K ;
MONNA, T ;
OCHI, H .
NUCLEAR MEDICINE COMMUNICATIONS, 1991, 12 (03) :235-242
[9]  
Taniguchi H, 1996, J NUCL MED, V37, P1522
[10]   Analysis of models for quantification of arterial and portal blood flow in the human liver using PET [J].
Taniguchi, H ;
Oguro, A ;
Koyama, H ;
Masuyama, M ;
Takahashi, T .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) :135-144