The hemodialysis catheter conundrum: Hate living with them, but can't live without them

被引:283
作者
Schwab, SJ [1 ]
Beathard, G
机构
[1] Duke Univ, Med Ctr, Durham, NC 27706 USA
[2] Austin Diagnost Clin, Austin, TX USA
关键词
dialysis; renal replacement therapy; arteriovenous fistula; thrombosis; infection; vascular access;
D O I
10.1046/j.1523-1755.1999.00512.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Hemodialysis requires reliable recurrent access to the circulation. On a chronic basis, this has been best provided by the use of arteriovenous fistulae and arteriovenous grafts. In recent years, hemodialysis catheters have come to play an increasingly important role in the delivery of hemodialysis. The use of both temporary as well as cuffed hemodialysis catheters has emerged as a significant boon for both patients and practicing nephrologists. The complications, however, associated with each of these hemodialysis catheters, both in terms of anatomic, thrombotic, and infectious issues, have emerged as a major problem with their continued use. This significant morbidity and complication rate has forced many nephrologists to face a basic conundrum: they have come to hate having to deal with the problems inherent in catheter usage, but the enormous utility of these devices have forced physicians to accept the fact they cannot live without them in their current practice. Methods. We used a comprehensive literature review to describe the types, use and dilemmas of hemodialysis catheters. Results. This article provides a comprehensive review of both the benefits inherent with the use of these hemodialysis catheters while cataloging their complications and offering some possible solutions. Conclusion. Hemodialysis vascular access catheters are essential in the maintenance of hemodialysis vascular access. However, they have a significant infectious, thrombotic, anatomic complication rate that are detailed with proposed problem-solving guidelines.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 72 条
[1]  
Agraharkar M, 1995, ASAIO J, V41, P169
[2]  
[Anonymous], 1997, Am J Kidney Dis, V30, pS67
[3]   Adequacy of haemodialysis with cuffed central-vein catheters [J].
Atherikul, K ;
Schwab, SJ ;
Conlon, PJ .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (03) :745-749
[4]   Infectious rates of central venous pressure catheters: Comparison between newly placed catheters and those that have been changed [J].
Badley, AD ;
Steckelberg, JM ;
Wollan, PC ;
Thompson, RL .
MAYO CLINIC PROCEEDINGS, 1996, 71 (09) :838-846
[5]   SUBCLAVIAN STENOSIS - A MAJOR COMPLICATION OF SUBCLAVIAN DIALYSIS CATHETERS [J].
BARRETT, N ;
SPENCER, S ;
MCIVOR, J ;
BROWN, EA .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1988, 3 (04) :423-425
[6]  
Beathard GA, 1999, J AM SOC NEPHROL, V10, P1045
[7]   THE USE OF DUAL LUMEN JUGULAR VENOUS CATHETERS AS DEFINITIVE LONG-TERM ACCESS FOR HEMODIALYSIS [J].
BLAKE, PG ;
HURAIB, S ;
WU, G ;
ULDALL, PR .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (01) :26-31
[8]  
Boelaert JR, 1996, INFECT CONT HOSP EP, V17, P809
[9]  
BOUR ES, 1990, SURG GYNECOL OBSTET, V171, P33
[10]   PREVENTION AND TREATMENT OF CENTRAL VENOUS CATHETER SEPSIS BY EXCHANGE VIA A GUIDEWIRE - A PROSPECTIVE CONTROLLED TRIAL [J].
BOZZETTI, F ;
TERNO, G ;
BONFANTI, G ;
SCARPA, D ;
SCOTTI, A ;
AMMATUNA, M ;
BONALUMI, MG .
ANNALS OF SURGERY, 1983, 198 (01) :48-52