Evaluation of different validation strategies and long term effects in NIR calibration models

被引:20
作者
Sileoni, Valeria [1 ]
Marconi, Ombretta [2 ]
Perretti, Giuseppe [2 ]
Fantozzi, Paolo [1 ]
机构
[1] Univ Perugia, Italian Brewing Res Ctr, I-06126 Perugia, Italy
[2] Univ Perugia, Dept Econ & Food Sci, I-06126 Perugia, Italy
关键词
Near infrared spectroscopy; Barley malt; Beer; Validation; Analyses; LEAST-SQUARES REGRESSION; QUALITY; MALT;
D O I
10.1016/j.foodchem.2013.04.110
中图分类号
O69 [应用化学];
学科分类号
070301 [无机化学];
摘要
Stable and reliable NIR calibration models for the barley malt quality assessment were developed and exhaustively evaluated. The measured parameters are: fine extract, fermentability, pH, soluble nitrogen, viscosity, friability and free-amino nitrogen. The reliability of the developed calibration models was evaluated comparing the classic leave-one-out internal validation with a more challenging one exploiting resampling scheme. The long-term effects, intended as possible alterations of the NIR method predictive power, due to the variation between samples collected in different years, were evaluated through an external validation which demonstrated the stability of the developed calibration models. Finally, the accuracy and the precision of the developed calibration models were evaluated in comparison with the reference methods. This exhaustive evaluation offers a realistic idea of the developed NIR methods predictive power for future unknown samples and their application in the beer industry. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2639 / 2648
页数:10
相关论文
共 29 条
[1]
Variable selection in regression-a tutorial [J].
Andersen, C. M. ;
Bro, R. .
JOURNAL OF CHEMOMETRICS, 2010, 24 (11-12) :728-737
[2]
[Anonymous], 2001, NEAR INFRARED TECHNO
[3]
[Anonymous], 2001, ASTM ANN BOOK STAND, P573
[4]
Black C., 2001, P 10 AUSTR BARL TECH
[5]
Romía MB, 2009, INFRARED SPECTROSCOPY FOR FOOD QUALITY ANALYSIS AND CONTROL, P51
[6]
Conzen J., 2006, Multivariate Calibration: A practical guide for developing methods in the quantitative analytical chemistry
[7]
A feasibility study on the use of visible and short wavelengths in the near-infrared region for the non-destructive measurement of wine composition [J].
Cozzolino, D. ;
Kwiatkowski, M. J. ;
Waters, E. J. ;
Gishen, M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (06) :2289-2295
[8]
Cruciani G., 1989, J CHEMOM, V3, P499
[9]
Dahm D.J., 2001, near-infrared technology in the agricultural and food industrious, P1
[10]
PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17